Genuine AirTAC filter regulator, order code GTFR20006LN from the GTFR200 range. The options this code selects are decoded below; series data follow the official AirTAC catalog.
The N in GTFR20006LN means no pressure gauge: this low-pressure AirTAC GT200 filter regulator regulates 0.15 - 0.4 MPa (20 - 58 psi) on 1/8 inch (06) PT ports without a gauge on the body, so it suits panels that already carry their own indicator or sensor. The standard 40 um element filters the air in the compact GT200 short-bowl body, the tightened derivative of GA200.
The PC bowl is drained by differential plus manual operation, and a mounting bracket is included because the code carries no J. With no K suffix, this build has no check valve, keeping the pneumatic path to the essentials.
| Order code | GTFR20006LN |
|---|---|
| Product | Filter Regulator |
| Port | 1/8" (06) |
| Type · gauge | Low-pressure (L) · No gauge (N) |
| Configuration | With bracket · 40 µm element · PT thread |
| Port | 1/8" (06), 1/4" (08) |
|---|---|
| Thread | PT (standard) |
| Filter element | 40 µm (standard), 5 µm (W) |
| Bowl | Short PC bowl |
| Drain | Differential + manual |
| Fluid | Air |
| Low-pressure (L) version | 0.15 – 0.4 MPa (20 – 58 psi) |
Source: AirTAC Products Catalog 2026A (p.235, PDF01-P0237), GT200 ordering code and specifications.
Pick GTFR20006LN when your cabinet already shows pressure elsewhere; add a fitted gauge by ordering GTFR20006L instead, or keep the gauge-free layout and gain a check valve with GTFR20006LNK. For a 1/4 inch line move to GTFR20008LN, and if you need set pressures beyond the L version's 0.4 MPa top end, the standard S type is the variant to select.
Control cabinets that already read pressure through their own gauge or transmitter, where the N-coded gaugeless head avoids a duplicated indicator on the regulator.
Light clamping, blowing and ejecting circuits specified in the 0.15 - 0.4 MPa (20 - 58 psi) range on a 1/8 inch (06) PT air line.
Shallow enclosures where the GT200 short PC bowl format and the included mounting bracket let the unit sit close to the panel wall without sacrificing the GA200 feature set.
Port 1/8 inch (06), PT thread, low-pressure range 0.15 - 0.4 MPa (20 - 58 psi), 40 um filter element, short PC bowl with differential and manual drain, mounting bracket included, no gauge (N) and no check valve. Fluid is air.
Yes: plan for an external gauge or use your panel's own sensor, since this regulator is delivered without one. GTFR20006L is the identical low-pressure unit with a gauge fitted if you would rather have the indication on the body.