Genuine AirTAC filter regulator, order code GTFR20006SJWK from the GTFR200 range. The options this code selects are decoded below; series data follow the official AirTAC catalog.
This GT200-series filter regulator combines filtering and pressure regulation in one short PC bowl body, the compact alternative to the deeper GA200 for cramped cabinets and manifolds. Condensate is handled by a differential drain that bleeds automatically, backed by a manual drain for dumping the bowl on demand.
The W in this order code selects the 5 um element instead of the catalog-standard 40 um, and K adds a check valve that protects downstream settings when upstream supply is interrupted. J deletes the mounting bracket, so confirm your mounting surface carries the unit directly. The standard S type ships with a pressure gauge fitted.
| Order code | GTFR20006SJWK |
|---|---|
| Product | Filter Regulator |
| Port | 1/8" (06) |
| Type · gauge | Standard (S) · With gauge (MPa/psi) |
| Configuration | No bracket (J) · 5 µm element (W) · PT thread · Check valve (K) |
| Port | 1/8" (06), 1/4" (08) |
|---|---|
| Thread | PT (standard) |
| Filter element | 40 µm (standard), 5 µm (W) |
| Bowl | Short PC bowl |
| Drain | Differential + manual |
| Fluid | Air |
| Low-pressure (L) version | 0.15 – 0.4 MPa (20 – 58 psi) |
Source: AirTAC Products Catalog 2026A (p.235, PDF01-P0237), GT200 ordering code and specifications.
Choose this code when your line is 1/8 in (06 port) and you need finer 5 um air with backflow protection. For 1/4 in piping step up to an 08 port code. If 40 um filtration is adequate and you want the bracket included, the sibling with check valve is GTFR20006SK; if you can accept the standard element but no bracket, drop only the K and keep W.
The 5 um element filters out finer particles than the standard 40 um, which suits delicate pneumatic sensors and measuring devices fed through a 1/8 in line.
A short PC bowl and 1/8 in PT ports keep the unit compact beside small grippers and cylinders, while the check valve holds the regulated setting during supply dips.
The fitted MPa/psi gauge and differential plus manual drain give repeatable, clean regulated air for test benches without needing a bracket on the frame.
Port: 1/8 in PT (06 code). Standard pressure type with MPa/psi gauge. Filter element: 5 um (W). Drain: differential plus manual. Check valve included (K). No mounting bracket (J). Short PC bowl, fluid: air.
The J in the order code deletes the bracket that a blank configuration includes. If the unit later needs to hang on a frame or panel, switch to the bracketed sibling in the same series and confirm details from the datasheet.