Genuine AirTAC filter regulator, order code GTFR20006SK from the GTFR200 range. The options this code selects are decoded below; series data follow the official AirTAC catalog.
Ordering GTFR20006SK keeps every standard convenience of the GT200 short-bowl filter regulator: because the code carries no J, the mounting bracket is included, and the 40 um element is the catalog default for general plant air. The short PC bowl fits where the full-depth GA200 body cannot.
The K suffix adds a check valve, the right choice when a downstream circuit must keep its regulated pressure through an upstream supply interruption. Condensate leaves through the differential plus manual drain, and the fitted gauge reads regulated pressure directly on the unit.
| Order code | GTFR20006SK |
|---|---|
| Product | Filter Regulator |
| Port | 1/8" (06) |
| Type · gauge | Standard (S) · With gauge (MPa/psi) |
| Configuration | With bracket · 40 µm element · PT thread · Check valve (K) |
| Port | 1/8" (06), 1/4" (08) |
|---|---|
| Thread | PT (standard) |
| Filter element | 40 µm (standard), 5 µm (W) |
| Bowl | Short PC bowl |
| Drain | Differential + manual |
| Fluid | Air |
| Low-pressure (L) version | 0.15 – 0.4 MPa (20 – 58 psi) |
Source: AirTAC Products Catalog 2026A (p.235, PDF01-P0237), GT200 ordering code and specifications.
This is the fully equipped 1/8 in standard code: gauge, bracket, 40 um element and check valve all present. Need finer 5 um air instead of 40 um? Move to GTFR20006SJWK, which also drops the bracket. Do not need the check valve? Choose a code without K. For 1/4 in lines, select the 08 port version.
Mounted on its included bracket beside a machine, the unit filters general plant air to 40 um and regulates it for local valves and actuators.
The check valve (K) keeps downstream pressure in holding or clamping circuits if the upstream supply drops, protecting the setting shown on the fitted gauge.
A compact short PC bowl with differential plus manual drain makes the unit easy to place on a workbench feeding 1/8 in tool lines.
Port: 1/8 in PT (06 code). Standard pressure type with MPa/psi gauge. Filter element: 40 um (standard). Drain: differential plus manual. Check valve included (K). Mounting bracket included (no J). Short PC bowl, fluid: air.
K adds a check valve to the regulator. When upstream pressure is lost, it helps the downstream side hold its regulated pressure instead of backflowing, which matters for clamping, holding and similar circuits.