Genuine AirTAC filter regulator, order code GTFR20006SN from the GTFR200 range. The options this code selects are decoded below; series data follow the official AirTAC catalog.
The N in GTFR20006SN removes the pressure gauge, leaving the regulator face clear for panels where a gauge already exists elsewhere on the manifold or where you plan to add your own instrument. Filtration stays at the standard 40 um element for general air service.
The rest of the configuration is the full default set: mounting bracket included (no J in the code), PT-threaded 1/8 in ports, and the short PC bowl of the GT200 series, which keeps the GA200 feature set in a smaller body. Note there is no K in this code, so it comes without a check valve, and condensate is removed by the differential plus manual drain.
| Order code | GTFR20006SN |
|---|---|
| Product | Filter Regulator |
| Port | 1/8" (06) |
| Type · gauge | Standard (S) · No gauge (N) |
| Configuration | With bracket · 40 µm element · PT thread |
| Port | 1/8" (06), 1/4" (08) |
|---|---|
| Thread | PT (standard) |
| Filter element | 40 µm (standard), 5 µm (W) |
| Bowl | Short PC bowl |
| Drain | Differential + manual |
| Fluid | Air |
| Low-pressure (L) version | 0.15 – 0.4 MPa (20 – 58 psi) |
Source: AirTAC Products Catalog 2026A (p.235, PDF01-P0237), GT200 ordering code and specifications.
Pick GTFR20006SN over the gauge-fitted GTFR20006S when your panel or manifold already shows regulated pressure and you want a clean regulator face. If you also need a check valve, step to GTFR20006SK, which returns the gauge and adds K. For finer 5 um air, look at a W-coded variant instead of the standard 40 um element here.
Where one common gauge serves several stations, this no-gauge (N) regulator avoids a duplicated dial and keeps the 1/8 in station feed simple.
The short PC bowl and included mounting bracket let the unit sit inside tight enclosures, with the 40 um element handling standard plant air.
Feeding small cylinders through 1/8 in PT ports, the regulator is set once and pressure is read on a separate panel instrument rather than on the unit.
Port: 1/8 in PT (06 code). Standard pressure type. No pressure gauge fitted (N). Filter element: 40 um (standard). Drain: differential plus manual. No check valve (no K). Mounting bracket included. Short PC bowl, fluid: air.
N deletes the pressure gauge that a blank code includes, so set and verify regulated pressure with an external gauge. Everything else stays standard, including the bracket, the 40 um element and the PT 1/8 in ports.