Genuine AirTAC filter regulator, order code GTFR20008LJNK from the GTFR200 range. The options this code selects are decoded below; series data follow the official AirTAC catalog.
The GTFR20008LJNK is a GT200-series filter regulator built for low-pressure circuits. Its L type regulates 0.15 to 0.4 MPa (20 to 58 psi), well below the standard setting band, and it mounts a 1/4 in (08) PT-threaded port on the short PC body that keeps the GA200 feature set in a smaller footprint. The N in the code means no pressure gauge is fitted, and J means no mounting bracket, so plan your panel space and pressure readout before ordering.
The trailing K adds a check valve, which holds downstream pressure if the upstream supply is interrupted, and the element stays the standard 40 um grade rather than the 5 um W option. Drain is differential plus manual, so the short PC bowl empties itself during normal flow and can be purged by hand.
| Order code | GTFR20008LJNK |
|---|---|
| Product | Filter Regulator |
| Port | 1/4" (08) |
| Type · gauge | Low-pressure (L) · No gauge (N) |
| Configuration | No bracket (J) · 40 µm element · PT thread · Check valve (K) |
| Port | 1/8" (06), 1/4" (08) |
|---|---|
| Thread | PT (standard) |
| Filter element | 40 µm (standard), 5 µm (W) |
| Bowl | Short PC bowl |
| Drain | Differential + manual |
| Fluid | Air |
| Low-pressure (L) version | 0.15 – 0.4 MPa (20 – 58 psi) |
Source: AirTAC Products Catalog 2026A (p.235, PDF01-P0237), GT200 ordering code and specifications.
Choose this code when your line runs 1/4 in PT, your working pressure sits inside 0.15 to 0.4 MPa (20 to 58 psi), and you want the check valve function. If you need finer 5 um filtration instead of the standard 40 um element, order GTFR20008LJNWK, which combines W with K. If you can rely on a simple bowl drain without backflow hold-up, GTFR20008LJNW drops the check valve. Codes without N add a pressure gauge, and codes without J include the mounting bracket.
Fixtures that must not exceed a 0.15 to 0.4 MPa (20 to 58 psi) setpoint get the L-type band, while the check valve holds the clamp if the plant supply dips.
Pilot and sensor loops fed at 1/4 in PT stay stable on the standard 40 um element, with the N no-gauge build monitored by the panel's own instruments.
The short-bowl GTFR200 body plus the J no-bracket build saves mounting space inside machine frames, and differential plus manual drainage suits enclosed cells.
Port: 1/4 in (08), PT thread. Type: low-pressure L, regulating 0.15 to 0.4 MPa (20 to 58 psi). Gauge: none (N). Bracket: none (J). Filter element: standard 40 um. Bowl: short PC, differential plus manual drain. Extras: check valve (K). Fluid: air.
Both share the same low-pressure band, 1/4 in PT port and no-gauge, no-bracket build, but GTFR20008LJNK keeps the standard 40 um element and adds a check valve to hold downstream pressure, while GTFR20008LJNW swaps to the 5 um element and omits the check valve.