Genuine AirTAC filter regulator, order code GTFR20008SJ from the GTFR200 range. The options this code selects are decoded below; series data follow the official AirTAC catalog.
The GTFR20008SJ is the 1/4 in (08) standard-pressure GT200 filter regulator ordered with the J option, which means it ships without the mounting bracket. The unit itself is unchanged: short PC bowl in the compact GT200 format, a gauge fitted as standard, and a filter that drains by differential pressure with a manual drain for service.
Ports are 1/4 in with PT threads and the 40 um element is the standard element. Choosing J is the right move when the unit will be panel mounted, screwed into an existing manifold, or built into equipment that provides its own fixing, so the bracket would simply be discarded.
| Order code | GTFR20008SJ |
|---|---|
| Product | Filter Regulator |
| Port | 1/4" (08) |
| Type · gauge | Standard (S) · With gauge (MPa/psi) |
| Configuration | No bracket (J) · 40 µm element · PT thread |
| Port | 1/8" (06), 1/4" (08) |
|---|---|
| Thread | PT (standard) |
| Filter element | 40 µm (standard), 5 µm (W) |
| Bowl | Short PC bowl |
| Drain | Differential + manual |
| Fluid | Air |
| Low-pressure (L) version | 0.15 – 0.4 MPa (20 – 58 psi) |
Source: AirTAC Products Catalog 2026A (p.235, PDF01-P0237), GT200 ordering code and specifications.
Compare this code with its siblings before ordering. GTFR20008S is the identical 1/4 in standard unit but with the bracket included, so order that one if you need to wall or machine mount the regulator. GTFR20008SJK keeps the no-bracket J option and adds a check valve (K). If your line is 1/8 in, the 06 port code applies, and the L type regulates 0.15-0.4 MPa (20-58 psi) where low-pressure control is needed; W selects a 5 um element instead of 40 um.
Builders who fix the regulator on their own sub-plate or inside a machine frame can order J and avoid paying for a bracket they will not use.
The 1/4 in PT ports let the unit screw straight into a prepared panel or manifold, with the fitted gauge still readable at the front of the assembly.
When replacing a similar unit that was never bracket mounted, the no-bracket build drops into the same pipe run without new fixing work.
Only the bracket. J means the unit is supplied without the mounting bracket; everything else stays as the 1/4 in (08) standard build: gauge fitted, 40 um element, PT thread, short PC bowl, differential plus manual drain.
Port 1/4 in (08), PT thread standard, S standard pressure type, pressure gauge fitted, 40 um filter element, no bracket (code J), short PC bowl, differential plus manual drain, fluid air.