Genuine AirTAC filter regulator, order code GTFR20008SJN from the GTFR200 range. The options this code selects are decoded below; series data follow the official AirTAC catalog.
The GTFR20008SJN is the gaugeless, bracketless build of the AirTAC GT200-series filter regulator for 1/4 in (08) lines. The N option deletes the pressure gauge and the J option omits the mounting bracket, so you get the shortest possible unit: the GT200 short PC bowl keeps GA200 features in a smaller body for tight panels. Air filtration uses the standard 40 um element, and the drain works on differential plus manual action.
PT thread is fitted as standard on both 1/4 in ports, so no thread suffix is needed in the order code. Because there is no gauge, read or set downstream pressure on a separate gauge point in your circuit.
| Order code | GTFR20008SJN |
|---|---|
| Product | Filter Regulator |
| Port | 1/4" (08) |
| Type · gauge | Standard (S) · No gauge (N) |
| Configuration | No bracket (J) · 40 µm element · PT thread |
| Port | 1/8" (06), 1/4" (08) |
|---|---|
| Thread | PT (standard) |
| Filter element | 40 µm (standard), 5 µm (W) |
| Bowl | Short PC bowl |
| Drain | Differential + manual |
| Fluid | Air |
| Low-pressure (L) version | 0.15 – 0.4 MPa (20 – 58 psi) |
Source: AirTAC Products Catalog 2026A (p.235, PDF01-P0237), GT200 ordering code and specifications.
Stay with GTFR20008SJN when your line is 1/4 in (08) and a panel or nearby regulator already carries a gauge; add N only if no gauge is wanted, since the plain GTFR20008S code ships with one fitted. If you need wall or frame mounting, drop the J and order GTFR20008S. On 1/8 in tubing use the 06 body instead. For lines running under 0.4 MPa, the L type (GTFR20008SLN) regulates 0.15 - 0.4 MPa (20 - 58 psi), while S covers standard pressure.
Compact short-bowl conditioning on a 1/4 in branch where panel space is tight and a separate precision gauge already monitors downstream pressure.
Filters machine air to 40 um at a 1/4 in PT drop, with the differential plus manual drain clearing bowl condensate at shift checks.
No gauge and no bracket to clear, so the unit slots into a manifold plate or existing bracket on legacy 1/4 in PT installs.
Port: 1/4 in (08), PT thread standard. Type: S, standard pressure. Gauge: none (N option). Bracket: none (J option). Element: 40 um standard. Bowl: short PC with differential plus manual drain. Fluid: air.
Both options are deliberate deletions in the ordering code: N removes the pressure gauge that the plain GTFR20008S carries, and J removes the mounting bracket included by default. Order those base codes instead if you want either item fitted from the factory.