Genuine AirTAC filter regulator, order code GTFR20008SK from the GTFR200 range. The options this code selects are decoded below; series data follow the official AirTAC catalog.
The GTFR20008SK is the 1/4 inch (code 08) port version of the AirTAC GTFR200 filter regulator from the GT200 series, ordered in standard (S) pressure type with a pressure gauge fitted. Its check valve (option K) lets downstream air hold its setting while the upstream side is vented or depressurized, and the integrated 40 um element removes particulates in one compact stage. The body uses PT thread as standard and comes with a mounting bracket already in the code.
Like every GTFR200, this unit carries a short PC bowl with differential plus manual drain, the compact GT200-format bowl that keeps the GA200 feature set in a smaller footprint for tight panels. If you want cleaner downstream air, the sibling GTFR20008SW swaps in a 5 um element instead of this standard 40 um one.
| Order code | GTFR20008SK |
|---|---|
| Product | Filter Regulator |
| Port | 1/4" (08) |
| Type · gauge | Standard (S) · With gauge (MPa/psi) |
| Configuration | With bracket · 40 µm element · PT thread · Check valve (K) |
| Port | 1/8" (06), 1/4" (08) |
|---|---|
| Thread | PT (standard) |
| Filter element | 40 µm (standard), 5 µm (W) |
| Bowl | Short PC bowl |
| Drain | Differential + manual |
| Fluid | Air |
| Low-pressure (L) version | 0.15 – 0.4 MPa (20 – 58 psi) |
Source: AirTAC Products Catalog 2026A (p.235, PDF01-P0237), GT200 ordering code and specifications.
Choose GTFR20008SK over GTFR20008SN or GTFR20008SNK if you want the factory-fitted pressure gauge for direct dial reading; the N codes ship without gauge. Against gauge-fitted GTFR20008S without K, this code adds the check valve for holding downstream pressure. If your line is 1/8 inch instead of 1/4 inch, step down to the 06 body (GTFR20006SK); for regulated pressures down to 0.15 - 0.4 MPa (20 - 58 psi), the L-type GTFR20008LK is the low-pressure alternative.
The K check valve retains downstream pressure when the supply side is shut off or exhausted, so a 1/4 inch PT-threaded circuit keeps its regulated setting between shifts.
With the fitted gauge, operators can read the regulated output directly at the 1/4 inch inlet station and drain the short PC bowl manually when the differential drain signals it.
The GT200 short PC bowl format keeps the filter regulator footprint small on machines where a full-depth GA200 body would not fit behind the panel.
Port: 1/4 inch (ordering code 08). Pressure type: standard (S) with a fitted pressure gauge. Configuration: 40 um filter element, PT thread, mounting bracket included, and check valve (K) fitted. Bowl: short PC bowl with differential + manual drain. Fluid: air. The L-type sibling regulates 0.15 - 0.4 MPa (20 - 58 psi); confirm the standard-type regulated range from the datasheet.
The K option in GTFR20008SK means air flows normally from inlet to outlet but is prevented from flowing back out through the unit, so downstream pressure is retained if upstream supply is interrupted. Note that a check valve also means downstream air cannot be vented backwards through this unit, so plan venting accordingly. The bracket is included, and the gauge ships fitted since this is not an N code.