Genuine AirTAC free mount cylinder, order code MU12X5 from the MU12 range. The options this code selects are decoded below; series data follow the official AirTAC catalog.
The AirTAC MU12X5 is the shortest-stroke free mount cylinder in the Dia 12 MU group: 5 mm of double acting travel on a square body that can be bolted from any of its four sides. The rod end leaves the factory as a female thread, so you attach your tooling with a stud or screw rather than an external nut. A locating boss on the front cover keeps positioning accurate over this very short travel, and the hard-anodized bore with a compact bidirectional seal holds up without lubrication.
This code carries no piston magnet, so it is intended for motion and force only, not position feedback. The body still has the sensor grooves for CMSH, DMSH or EMSH sensors, so if you later need end-of-stroke detection, order the magnetized MU12X5S instead. It runs on filtered air at 0.15-0.7 MPa through M5x0.8 ports and needs no lubrication.
| Order code | MU12X5 |
|---|---|
| Product | Free Mount Cylinder |
| Stroke | 5 mm |
| Magnet | No magnet |
| Rod end | Female thread |
| Action | Double acting |
|---|---|
| Bore / rod | Ø12 / Ø6 mm |
| Standard strokes | 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 mm (max. 50 mm) |
| Force at 0.5 MPa | Push 56.5 N · pull 42.4 N |
| Port | M5×0.8 |
| Fluid | Air (filtered by 40 µm element) |
| Operating pressure | 0.15-0.7 MPa |
| Proof pressure | 1.2 MPa (175 psi) |
| Temperature | -20 to +70 °C |
| Piston speed | 30-500 mm/s |
| Cushion | Bumper |
| Lubrication | Not required |
Source: AirTAC Products Catalog 2026A (PDF01-P0498..P0499), MU series theoretical force, specifications, strokes and ordering code.
Pick MU12X5 when the task needs a short 5 mm push, such as part seating, ejection or a small clamping step; longer travels step up through MU12X10, MU12X15 and up to the 50 mm MU12X50. This code has a female rod thread; if your linkage needs a male stud, order MU12X5B, and if you need position sensing, add the magnet with MU12X5S. All four share the same Dia 12 bore and transverse body mounting; the axial-mounted alternative is the R version.
The 5 mm stroke seats small components into fixtures with 56.5 N of push force at 0.5 MPa, and the front-cover locating boss keeps the die or nest aligned.
Bolted from any of the four body sides, the MU12X5 clamps tiny parts in tight fixtures where a tie-rod cylinder would not fit, using M5x0.8 plumbing.
Several MU12X5 bodies mount side by side on a multi-station dial or indexing plate, each doing a short 5 mm eject or press move in the same footprint.
Dia 12 mm bore with Dia 6 mm rod, 5 mm stroke, double acting, push 56.5 N and pull 42.4 N at 0.5 MPa, operating pressure 0.15-0.7 MPa, M5x0.8 port, bumper cushion, piston speed 30-500 mm/s, temperature -20 to +70 C, female rod thread, no magnet.
The body already has the sensor grooves for CMSH, DMSH or EMSH sensors, which fit without brackets, but detection needs a magnet on the piston. This MU12X5 code has no magnet, so for sensing order the MU12X5S variant instead, or confirm the sensor fit from the datasheet.