The AirTAC Airtac SC50 Standard Cylinder SC50X1860 is a genuine double-acting standard air cylinder with a Ø50mm bore and 1860mm stroke, PT1/4 air ports and adjustable end cushioning. It is used for push, pull, lift and clamp motion in industrial automation.
The AirTAC SC50X1860 is a double-acting single-rod pneumatic cylinder with a 50 mm bore and an extra-long 1860 mm stroke, built for linear applications that demand extended reach. At 0.5 MPa it generates 982 N of pushing force and 825 N pulling force, while at the maximum operating pressure of 0.9 MPa the thrust rises to 1767 N. The cylinder features a 20 mm diameter piston rod with M16x1.5 male threads, PT1/4 ports, and a 21 mm adjustable air cushion at each end to decelerate the piston smoothly.
This 1860 mm stroke exceeds the standard maximum of 1200 mm for the 50 mm bore, making it a non-standard, made-to-order configuration. The body length A is 150 mm, giving a total extended length of approximately 2010 mm. With such a long, slender rod, external guides or a guided cylinder should be considered if the load applies any side force, to prevent rod bending and premature bearing wear. The default TPU seals and NBR O-rings suit operating temperatures from -20 to +70 °C.
| Model | Airtac SC50 Standard Cylinder SC50X1860 |
|---|---|
| Series | SC standard tie-rod cylinder |
| Bore size | Ø50 mm |
| Stroke | 1860 mm |
| Acting type | Double acting |
| Port size | PT1/4 |
| Rod thread | M16×1.5 |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Operating pressure | 0.15 – 1.0 MPa |
| Proof pressure | 1.5 MPa |
| Temperature | -20 to +70 °C |
| Speed range | 30 – 800 mm/s |
| Cushion | Adjustable, 21 mm |
| Max stroke | Up to 1200 mm |
Specifications follow the official AirTAC SC series datasheet. Operating pressure 0.15–1.0 MPa, proof pressure 1.5 MPa, temperature −20 to +70 °C. Confirm against the product label before installation. Thread options: PT (standard) / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 982 N | 825 N |
| 0.7 MPa | 1374 N | — |
| Max (approx.) | 200 kgf | |
Actual usable force is lower than theoretical due to friction and back-pressure. Size with a safety margin.
| SC | Standard tie-rod cylinder series. |
|---|---|
| 50 | Bore size in mm. |
| ×1860 | Stroke length in mm. |
| -S | Optional built-in magnet for sensor position sensing. |
Related variants: SCD (double rod), SCJ (adjustable stroke), SCT (multi-position). Seals: TPU standard / H = Viton / N = NBR. Thread: blank = PT, G = G thread.
Pushes pallets or large boxes across wide roller conveyors where a standard-stroke cylinder falls short. The 1860 mm stroke crosses an entire conveyor zone in one motion.
Raises and lowers large sheets or panels in a gantry with guided vertical travel. The 982 N push force at 0.5 MPa lifts moderate loads, while the adjustable cushion softens the end-of-stroke stop.
Opens and closes long rows of roof vents. The extended 1860 mm stroke provides the wide angular throw needed, and the tie-rod design withstands humid, dusty environments when properly filtered.
Choose the SC50X1860 when you need a 50 mm bore with a stroke beyond the standard 1200 mm limit. If your force requirement is lower, stepping down to a 40 mm bore (628 N push at 0.5 MPa) can reduce air consumption; for higher force, the 63 mm bore provides 1559 N at the same pressure. This long-stroke cylinder must be protected from side loads—the 20 mm rod is unsupported over a very long distance and will bend under lateral force. Always use an external linear guide or rod-alignment coupler.
For a direct replacement, match five points: bore (50 mm), stroke (1860 mm), port thread (PT1/4), mounting style (basic, no bracket), and magnet option (none). This is a tie-rod cylinder, not an ISO 15552 profile cylinder, so it is dimensionally shorter and not interchangeable with ISO 15552 types.
Quick checklist
At 0.7 MPa supply pressure, the SC50X1860 produces 1374 N of force when extending (push) and approximately 1155 N when retracting (pull). The theoretical maximum force at 1.0 MPa is 200 kgf. Always size the cylinder using the force at your minimum expected operating pressure, not the theoretical maximum.
It is strongly recommended to use an external guide or rod support for any stroke over 300 mm, and it is essential for an 1860 mm stroke. The 20 mm diameter rod is not designed to carry side loads over this length. Without guidance, side forces will bend the rod, damage the piston rod bearing, and cause premature seal failure. The cylinder should only be used for purely axial push-pull motions unless an external guide rail is fitted.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.