Genuine AirTAC piston pressure regulator, order code SDR20006J1 from the SDR range. The options this code selects are decoded below; series data follow the official AirTAC catalog.
The SDR20006J1 matches the SDR200 piston back-pressure regulator on a PT1/8 port, with two ordering codes doing specific work: J removes the mounting bracket, and 1 fits the MPa scale pressure gauge. The bracket-free body is aimed at builders who panel-mount, manifold-mount, or fasten the regulator by its own connections rather than a foot.
Regulating behavior is unchanged by the J code: this is the standard type covering 0.05-0.9 MPa, with maximum operating pressure 1.0 MPa (145 psi), proof pressure 1.5 MPa (215 psi), and a -20 to +70 C temperature window on air. Output pressure stays stable, keeping the series reputation as a simple, small and cost-effective choice for circuits that do not need high regulating accuracy.
| Order code | SDR20006J1 |
|---|---|
| Product | Piston Pressure Regulator |
| Model and port | SDR200 · PT1/8 |
| Type and bracket | Standard, no bracket (J) |
| Pressure gauge | MPa gauge (1) |
| Structure | Piston back-pressure type |
|---|---|
| Fluid | Air |
| SDR100 ports | M5 / 1/8 |
| SDR200 ports | 1/8 / 1/4 |
| Regulating range | 0.05-0.9 MPa (standard), 0.03-0.4 MPa (L) |
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature | -20 to +70 °C |
Source: AirTAC Products Catalog 2026A (PDF01-P0274), SDR series specifications and ordering code.
Choose SDR20006J1 over SDR200061 only when you do not want the bracket: both share the PT1/8 port, standard 0.05-0.9 MPa range and MPa gauge, but J deletes the mounting foot. If you would rather read pressure on your own panel instruments, SDR20006N removes the gauge as well. For setpoints that never pass 0.4 MPa, SDR20006JL is the low-pressure variant of the same bracket-free unit, and SDR20008 changes the port to 1/4.
Without the bracket, the PT1/8 body slots directly into manifold plates or control panels, with the MPa gauge remaining visible for local checks up to the 0.9 MPa ceiling.
Machine builders who supply their own fastening can specify code J and still keep the full standard range 0.05-0.9 MPa, 1.0 MPa (145 psi) max pressure, and an MPa readout on the unit.
Retrofitting regulation into crowded cabinets is easier when the bracket is deleted: the compact SDR200 body needs only its PT1/8 connections and the space around the MPa gauge.
SDR200 series piston back-pressure regulator, PT1/8 port, standard regulating range 0.05-0.9 MPa, max pressure 1.0 MPa (145 psi), proof pressure 1.5 MPa (215 psi), air at -20 to +70 C. Code J means no mounting bracket; code 1 fits the MPa scale gauge.
Code J deletes the mounting bracket, so the unit arrives without a foot; the blank option is the version supplied with a bracket (for example SDR200061). Everything else in SDR20006J1, including the PT1/8 port, MPa gauge and the 0.05-0.9 MPa range, matches the bracketed sibling. Confirm mounting dimensions from the datasheet.