Genuine AirTAC piston pressure regulator, order code SDR200081 from the SDR range. The options this code selects are decoded below; series data follow the official AirTAC catalog.
This SDR200 code pairs the 1/4 port size with PT threading, the standard regulating range and a factory-fitted pressure gauge. As a piston back-pressure regulator it is simple, small and cost-effective, with output pressure that stays stable on circuits that do not demand high regulating accuracy.
Nothing has been deleted from this build: the trailing 1 orders the MPa gauge scale, and the blank in the bracket position means the mounting bracket is included. With a 1.0 MPa (145 psi) maximum operating pressure, 1.5 MPa proof pressure and a -20 to +70 C window, it installs as a single unit straight onto the line.
| Order code | SDR200081 |
|---|---|
| Product | Piston Pressure Regulator |
| Model and port | SDR200 · PT1/4 |
| Type and bracket | Standard, with bracket |
| Pressure gauge | MPa gauge (1) |
| Structure | Piston back-pressure type |
|---|---|
| Fluid | Air |
| SDR100 ports | M5 / 1/8 |
| SDR200 ports | 1/8 / 1/4 |
| Regulating range | 0.05-0.9 MPa (standard), 0.03-0.4 MPa (L) |
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature | -20 to +70 °C |
Source: AirTAC Products Catalog 2026A (PDF01-P0274), SDR series specifications and ordering code.
Choose SDR200081 when you need a PT1/4 connection and want the regulator secured out of the box, because the bracket is standard here while code J on SDR20008J1 removes it. If your working setpoint never rises above 0.4 MPa, the low-pressure SDR20008L1 covers 0.03-0.4 MPa instead; for a 1/8 PT port move to SDR200061, and for G threads paired with a bar scale the ordering table points to SDR20008G1.
Set a steady downstream pressure on a 1/4 PT air circuit where good value matters more than fine regulating accuracy.
The scale-1 gauge reads directly in MPa, so technicians can verify the 0.05-0.9 MPa setting against drawings written in the same units.
Fix the regulator to a machine frame or panel wall using the supplied bracket rather than stressing the piping.
PT1/4 ports, standard regulating range 0.05-0.9 MPa, maximum operating pressure 1.0 MPa (145 psi), proof pressure 1.5 MPa, fluid air, temperature -20 to +70 C, MPa-scale gauge and mounting bracket both included.
It selects the gauge scale: 1 is MPa (standard with PT thread), 2 is psi (paired with NPT thread) and 3 is bar (paired with G thread). Ordering the code with N instead would delete the gauge entirely.