The AirTAC GFR300C08AC3T AirTAC Filter Regulator NPT1/4 is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR300C08AC3T is an AirTAC GFR300 filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This 300-size unit is fitted with 1/4 in NPT ports, a 40 um filter element, an automatic drain, and a round pressure gauge reading in bar. The regulator adjusts from 0.15 to 0.9 MPa (20-130 psi), the maximum inlet pressure is 1.0 MPa (145 psi), and the operating temperature range is -5 to 70 C (non-freezing). A mounting bracket is included.
This is a genuine AirTAC part. The GFR family is available in sizes 200, 300, 400 and 600 with ports from 1/8 to 1 in, and with manual, automatic or differential-pressure drains, 40 um or 5 um (code W) filtration, square or round gauges in MPa, psi or bar scales, and PT, G or NPT threads. Flow is published as curves rather than a single rated figure, so ask us to confirm flow and datasheet details for your application.
| Model | GFR300C08AC3T AirTAC Filter Regulator NPT1/4 |
|---|---|
| Series | GFR300 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR300 | G-series filter regulator, 300 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR300 · See datasheet · 40 µm |
|---|---|
| One size down | GFR200 |
| One size up | GFR400 |
| Add lubrication | GFC300-C0 (two-unit set) |
Conditioning the shop-air feed that actuates tool clamps, chucks and part ejectors on a CNC machining centre, with the automatic drain clearing collected condensate.
Supplying filtered, regulated air to the cylinders and grippers on a carton-forming and case-sealing line, keeping water and scale out of valve seals.
Regulating air to the vacuum ejectors and gripper cylinders of a robotic pick-and-place cell on an assembly line, with the 40 um element guarding downstream components.
Choose the size by port and flow: this 300 unit carries 1/4 in NPT ports, and stepping up to 400 or 600 gives larger ports and more flow. Drain type matters: the automatic drain on this unit discharges condensate without attention, while manual and differential-pressure drains are also available in the family. Filtration is 40 um standard; specify code W for 5 um where finer protection is needed. Gauge scale (MPa, psi or bar) and thread (PT standard, G or NPT to order) are decodable options, and the bracket can be included or omitted (code J). Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR300 as curves rather than a single rated figure, so we do not quote a number here. Send us your flow and pressure requirements and we will confirm the sizing from the datasheet before you order.
This GFR300 carries the automatic drain (code A), which discharges collected condensate without manual attention. The family also offers a manual drain (M) and a differential-pressure drain as the default. Note that the regulation range differs by drain type: automatic and differential-pressure versions adjust from 0.15 to 0.9 MPa (20-130 psi), while manual-drain versions adjust from 0.05 to 0.9 MPa (7-130 psi).
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.