The AirTAC GFR300C08AJC3T AirTAC Filter Regulator NPT1/4 is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR series combines filtration and pressure regulation in a single body: compressed air passes a filter element that removes water and particulate, then a regulator that sets the downstream pressure. This GFR300C08AJC3T is the size 300 unit with a 1/4 in NPT port, automatic drain, standard 40 um filter element and a round pressure gauge scaled in bar. Maximum inlet pressure is 1.0 MPa (145 psi), the regulation range is 0.15-0.9 MPa (20-130 psi), and the operating temperature is -5 to 70 C (non-freezing). The size 300 bowl is polycarbonate (PC), and no mounting bracket is fitted on this configuration.
This is a genuine AirTAC part. The GFR family is offered in sizes 200, 300, 400 and 600 with ports from 1/8 to 1 in, and with a choice of drain type, 40 um or 5 um filtration, gauge style and scale, PT, G or NPT thread, and bracket or no bracket. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and the sizing for your application on request.
| Model | GFR300C08AJC3T AirTAC Filter Regulator NPT1/4 |
|---|---|
| Series | GFR300 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR300 | G-series filter regulator, 300 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR300 · See datasheet · 40 µm |
|---|---|
| One size down | GFR200 |
| One size up | GFR400 |
| Add lubrication | GFC300-C0 (two-unit set) |
At each spray-booth drop, the unit filters water and particulate out of the supply and holds the atomising pressure at the set point, protecting the finish on vehicle panels.
Feeding the pneumatic sealers and product pushers on a packaging conveyor, the unit delivers clean air held at the regulated pressure so the cylinders cycle consistently shift after shift.
On a test bench, the regulator sets the supply pressure to the device under test while the 40 um element keeps water and debris away from the instrumentation connected to the circuit.
Choose the size and port by the air demand of your line: sizes step through 200, 300, 400 and 600 with ports from 1/8 to 1 in, and the published flow curves - not a single rating - define the right step, so send us your demand and we will confirm sizing before you order. On this unit the choices are already set: automatic drain, 40 um standard filtration, round gauge scaled in bar, NPT thread and no bracket. If you would rather have manual or differential-pressure draining, 5 um filtration (code W), a square gauge or an MPa or psi scale, PT or G thread, or a mounting bracket, those are order options across the GFR range.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR300 as curves, not as a single rated number, so we do not quote a figure. Send us your line pressure and air demand and we will confirm the sizing from the datasheet on request.
The A in the code means the bowl expels collected condensate automatically instead of relying on manual draining. Manual and differential-pressure drains are order options on the GFR range if your maintenance routine prefers them.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.