The AirTAC GFR300C08ALC1T AirTAC Filter Regulator NPT1/4 Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR300C08ALC1T is an AirTAC GFR300 filter regulator: water and particulate removal plus pressure regulation in a single body. This configuration is built on the size-300 body with a 1/4 in NPT port, an automatic drain that discharges collected condensate without manual attention, a 40 um filtration element (the standard grade), the low-pressure regulator type, a round pressure gauge with MPa scale, a mounting bracket, and no reverse/check valve. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing.
This is a genuine AirTAC part. The GFR family is offered in sizes 200, 300, 400 and 600 with PT, G or NPT threads, differential-pressure, automatic or manual drains, a 5 um (code W) element option, and gauge scales in MPa, psi or bar. Flow is published as curves rather than a single rating, so ask us to confirm the datasheet figures for your application.
| Model | GFR300C08ALC1T AirTAC Filter Regulator NPT1/4 Low-Pressure |
|---|---|
| Series | GFR300 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR300 | G-series filter regulator, 300 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR300 · See datasheet · 40 µm |
|---|---|
| One size down | GFR200 |
| One size up | GFR400 |
| Add lubrication | GFC300-C0 (two-unit set) |
Feeds film-sealing cylinders and low-pressure clamp actuators on a packaging machine, delivering cleaned air and holding a steady reduced pressure for gentle, repeatable actuation.
Supplies filtered, regulated air to pneumatic swing clamps and push cylinders on a machining or assembly fixture, protecting seals from water and debris while keeping clamp pressure stable.
Provides low-pressure instrument and actuator air on pilot plants and test rigs, where a 40 um element and automatic drain keep supply air dry and the MPa gauge gives a clear local reading.
Choose the size and port step against the air demand of the circuit: this unit is size 300 with a 1/4 in NPT port, and larger sizes carry larger ports and more flow. Drain type is a real choice - automatic (as fitted here), manual, or differential-pressure. Filtration grade is 40 um standard or 5 um with code W. Gauge scale can be MPa, psi or bar, and the thread can be ordered as PT, G (BSPP) or NPT. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves, not as a single rated figure, so we do not quote a number here. Send us your application details and we will confirm the flow and datasheet figures for GFR300C08ALC1T on request.
This unit carries the L code, so its regulator is the low-pressure type rather than the standard version. The exact adjustment range for the low-pressure type is not published in the sheet we work from, so we confirm it on request; the unit still accepts up to 1.0 MPa (145 psi) inlet.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.