verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR300 · Filter Regulator (filter + regulator in one body)

GFR300C08ALC2G AirTAC Filter Regulator G1/4 Auto Drain

The AirTAC GFR300C08ALC2G AirTAC Filter Regulator G1/4 Auto Drain is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$58.21 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR300C08ALC2G AirTAC Filter Regulator G1/4 Auto Drain

The GFR300C08ALC2G is an AirTAC GFR filter regulator: a unit that removes water and particulate from compressed air and regulates downstream pressure in one body. This configuration is size 300 with a 1/4 in G (BSPP) port, an automatic drain that ejects collected condensate without anyone having to operate it, the standard 40 um filter element, and the low-pressure regulator type. It carries the round external pressure gauge set to a psi scale, includes a mounting bracket, and has no reverse (check) valve fitted.

This is a genuine AirTAC part. The GFR range spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 in, a choice of differential-pressure, automatic or manual drain, an optional 5 um element (code W), gauge scales in MPa, psi or bar, and PT, G or NPT threads. Maximum inlet pressure is 1.0 MPa (145 psi), the working temperature is -5 to 70 C (non-freezing), and the size 300 bowl is polycarbonate. The exact adjustment range of the low-pressure type is not published in the material we hold, so we confirm it on request; flow is likewise published as curves rather than a single rating, and we will confirm figures from the datasheet for your application.

GFR300C08ALC2G AirTAC Filter Regulator G1/4 Auto Drain Technical Specifications

ModelGFR300C08ALC2G AirTAC Filter Regulator G1/4 Auto Drain
SeriesGFR300 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR300C08ALC2G AirTAC Filter Regulator G1/4 Auto Drain

GFR300G-series filter regulator, 300 body — sets the port range.
C0Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR300 · See datasheet · 40 µm
One size downGFR200
One size upGFR400
Add lubricationGFC300-C0 (two-unit set)

Where the GFR300C08ALC2G AirTAC Filter Regulator G1/4 Auto Drain Is Used

factory

Bottling-line actuator air

Filtered and regulated air for the cylinder-driven capping, filling and reject stations on a beverage bottling line, with the automatic drain handling condensate at an out-of-the-way drop.

precision_manufacturing

CNC workholding clamps

Supplying low-pressure regulated air to pneumatic clamps and swing cylinders on a machining cell, where the psi-scale gauge lets the setter read clamp pressure directly.

conveyor_belt

Conveyor divert and stop gates

Regulated air to diverters, stoppers and pusher cylinders on a distribution conveyor, with 40 um filtration protecting the solenoid valves that pilot them.

Is the GFR300C08ALC2G AirTAC Filter Regulator G1/4 Auto Drain the Right Unit?

Pick the size and port against the air consumption of the circuit: this unit is size 300 with a 1/4 in G thread, and larger sizes in the range carry larger ports and more flow. Drain type is a real choice - automatic (as here) suits drops that are rarely visited, manual gives deliberate control, and the differential-pressure default drains as the element loads up. Filter grade is 40 um standard or 5 um with code W; gauge scale is MPa, psi or bar; thread is PT as standard with G and NPT as order options; a bracket is included on this unit. Because flow is published as curves and not as a single rated figure, send us your consumption and line pressure and we will confirm sizing from the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR300C08ALC2G AirTAC Filter Regulator G1/4 Auto Drain FAQ

AirTAC publishes flow for the GFR series as curves, not as a single rated figure, so we do not quote a number here. Send us your line pressure and air consumption and we will confirm the sizing from the datasheet on request.

The automatic drain fitted to this unit ejects collected condensate by itself, which suits installation points that are rarely visited. A manual drain discharges only when operated, and the differential-pressure default drains as the element loads. All three are catalogue choices across the GFR range, and the drain code in the model tells you which one is fitted.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR300C08ALC2G AirTAC Filter Regulator G1/4 Auto Drain

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR300C08ALC2G and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.