The AirTAC GFR300C08ALC2WGK AirTAC Filter Regulator G1/4, 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$69.60 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR300C08ALC2WGK AirTAC Filter Regulator G1/4, 5 um

The GFR300C08ALC2WGK is an AirTAC GFR-series filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in one compact body. This configuration sits on the size-300 frame with a G1/4 (BSPP) port, a 5 um filtering element for finer air than the 40 um standard grade, an automatic drain that ejects collected condensate without manual attention, a low-pressure regulator type, a round external gauge scaled in psi, and a built-in reverse (check) valve. Mounting bracket included; metal bowl.

This is a genuine AirTAC part from the GFR range, published in sizes 200, 300, 400 and 600 with ports from 1/8 to 1 inch, and catalogue options covering drain type, filter grade, gauge style and scale, thread form (PT standard; G and NPT to order) and bracket. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application on request before ordering.

GFR300C08ALC2WGK AirTAC Filter Regulator G1/4, 5 um Technical Specifications

ModelGFR300C08ALC2WGK AirTAC Filter Regulator G1/4, 5 um
SeriesGFR300 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR300C08ALC2WGK AirTAC Filter Regulator G1/4, 5 um

GFR300G-series filter regulator, 300 body — sets the port range.
C0Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR300 · See datasheet · 40 µm
One size downGFR200
One size upGFR400
Add lubricationGFC300-C0 (two-unit set)

Where the GFR300C08ALC2WGK AirTAC Filter Regulator G1/4, 5 um Is Used

valve

Pneumatic valve supply on a packaging line

Feeding clean, regulated air to directional control valves on a carton-forming and sealing machine, where the 5 um element helps keep spool valves free of particulate and the automatic drain handles condensate between shifts.

science

Instrument air at a laboratory bench

Supplying reduced-pressure air to analytical instruments or test rigs that cannot take full line pressure - the low-pressure regulator type and the psi-scaled round gauge make setpoints easy to read and verify at the bench.

precision_manufacturing

Air cylinders on an assembly fixture

Regulating supply to clamp and lift cylinders on a small assembly fixture, with the built-in check valve holding the downstream circuit against momentary supply dips and the G1/4 port matching standard fitting hardware.

Is the GFR300C08ALC2WGK AirTAC Filter Regulator G1/4, 5 um the Right Unit?

The real, decodable choices: step between sizes 200/300/400/600 to match the port and flow path your line needs; choose automatic drain (as fitted here) where the bowl cannot be attended daily, manual where you want positive control, or differential-pressure as the default; pick the 5 um element (code W, fitted on this unit) when downstream valves or instruments need finer air than the 40 um standard. This unit carries a round external gauge scaled in psi; the embedded square gauge and MPa/bar scales are the other catalogue options. Thread is G (BSPP) here; PT is the standard thread and NPT is an order option. Flow is published as curves, not a single rating - send us your flow and pressure targets and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR300C08ALC2WGK AirTAC Filter Regulator G1/4, 5 um FAQ

AirTAC publishes GFR flow as curves rather than a single rated figure, so we do not quote a number here. Tell us your required flow and working pressure and we will confirm the sizing from the datasheet on request before you order.

The automatic drain ejects collected condensate on its own, so the bowl does not need manual bleeding on attended equipment. The 5 um element (code W) filters more finely than the 40 um standard, which suits downstream valves and instruments. This is the low-pressure regulator type; its exact adjustment range is not published in the catalogue, so we confirm it on request.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR300C08ALC2WGK AirTAC Filter Regulator G1/4, 5 um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR300C08ALC2WGK and will confirm price, stock and lead time — usually within 7-8 hours.