The AirTAC GFR300C08C1T AirTAC Filter Regulator NPT1/4 is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR300C08C1T is a filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This 300-size unit is threaded NPT1/4, carries the standard 40 um filter element, and drains condensate by differential pressure, so the bowl self-drains as air flows through. The 300-size bowl is polycarbonate. A round pressure gauge with an MPa scale is fitted, the regulator is the standard type with a 0.15-0.9 MPa (20-130 psi) adjustment range, and a mounting bracket is included.
This is a genuine AirTAC part. The GFR family is available in sizes 200, 300, 400 and 600 with port sizes from 1/8 to 1 inch, and with a choice of drain type, 5 um (code W) or 40 um filtration, gauge type and scale, and G or NPT thread options. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rating, so ask us to confirm figures from the datasheet for your application.
| Model | GFR300C08C1T AirTAC Filter Regulator NPT1/4 |
|---|---|
| Series | GFR300 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR300 | G-series filter regulator, 300 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR300 · See datasheet · 40 µm |
|---|---|
| One size down | GFR200 |
| One size up | GFR400 |
| Add lubrication | GFC300-C0 (two-unit set) |
Point-of-use filtration and regulation ahead of the pneumatic cylinders and grippers on a bottling line, keeping water and debris out of the valves that index the conveyor.
A filtered, regulated feed for the seal jaws and vacuum cups on a carton packaging machine, with the fitted MPa gauge giving operators a local setpoint reference.
Mounted at the air drop of a CNC machining cell to condition the supply to tool-change cylinders and clamps, with the included bracket fixing the unit to the panel.
Size the unit by the port and flow step: this 300-size unit covers 1/4-inch (08) piping, and moving up a size increases both port and flow capacity. Choose the drain to match the installation: differential-pressure (this unit) drains automatically with flow, automatic (code A) suits lines with intermittent flow, and manual (code M) needs periodic draining. Filter grade is 40 um standard; specify W for 5 um where finer protection is needed. Gauge type and scale (MPa, psi or bar), thread (PT is the standard, G and NPT are order options) and the mounting bracket are all decodable choices. Because flow is published as curves rather than a single rated figure, send us your application details and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves, not as a single rated figure, so we do not quote a number here. Tell us your application and we will confirm the flow figures from the datasheet on request.
This unit drains condensate by differential pressure: the bowl drains automatically as air flows through, with no operator action. If the unit sits on a line with intermittent flow, the automatic drain (code A) or manual drain (code M) versions may suit better - we can confirm the available options on request.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.