The AirTAC GFR300C15LC2GK AirTAC Filter Regulator G1/2 Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR300C15LC2GK is an AirTAC GFR300 filter regulator: one body that removes water and particulate from compressed air and regulates downstream pressure. This configuration has G1/2 (BSPP) ports, a 40 um filter element, a differential-pressure drain and a metal bowl. The regulator is the low-pressure type, fitted with an external round gauge reading in psi, and a built-in check valve (code K) is included. The unit comes with a mounting bracket. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing.
This is a genuine AirTAC part. The GFR family covers sizes 200, 300, 400 and 600 with ports from 1/8 to 1 inch, and options that include manual or automatic drains, a 5 um element (code W), gauge scales in MPa, psi or bar, and G or NPT threads as alternatives to the PT standard. Flow for this series is published as curves rather than a single rated figure, so ask us to confirm sizing and any datasheet figure against your application before ordering.
| Model | GFR300C15LC2GK AirTAC Filter Regulator G1/2 Low-Pressure |
|---|---|
| Series | GFR300 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR300 | G-series filter regulator, 300 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR300 · See datasheet · 40 µm |
|---|---|
| One size down | GFR200 |
| One size up | GFR400 |
| Add lubrication | GFC300-C1 (two-unit set) |
Supplying filtered, regulated air to clamp cylinders on an assembly-line fixture, where the low-pressure regulator holds a reduced set point for controlled clamping.
Feeding spray guns in a paint booth with air stripped of water and particulate, held at a steady reduced pressure for consistent finish work.
Conditioning the supply to low-pressure actuation circuits on packaging machinery, with the built-in check valve blocking reverse flow if the upstream feed is lost.
The real, decodable choices on this series are the size and port (200/300/400/600 with ports from 1/8 to 1 inch, stepped against the flow your line needs), the drain type (differential-pressure as here, automatic, or manual), the filter grade (40 um standard, 5 um with code W), the gauge (embedded square as standard or an external round gauge, scaled in MPa, psi or bar), the thread (PT standard, with G or NPT as order options), the low-pressure regulator type for circuits that call for reduced set points, and the bracket and check-valve options. Flow is published as curves, not a single rating, so send us your application details and we will confirm sizing from the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR300 series as curves rather than a single rated figure, so we do not quote a number here. Send us your line pressure, port size and air demand, and we will confirm the flow and the full datasheet figures for this model on request.
This unit is the low-pressure regulator variant of the GFR300, fitted with an external round gauge scaled in psi. The exact adjustment range for the low-pressure type is not published in our data, so confirm the set-point range with us against your application before ordering. Maximum inlet pressure is 1.0 MPa (145 psi) and the working range is -5 to 70 C, non-freezing.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.