The AirTAC GFR300C15LF2T AirTAC Filter Regulator NPT 1/2 in is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR300C15LF2T is a filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This 300-size unit has 1/2 in NPT ports, a 40 um filter element, a differential-pressure drain and a low-pressure regulator type, with an embedded square gauge reading in psi. The bowl is metal, a mounting bracket is included, and no reverse (check) valve is fitted. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing.
This is a genuine AirTAC part from the GFR series, which spans sizes 200, 300, 400 and 600 with port sizes from 1/8 to 1 in and PT, G or NPT threads. Other options include a 5 um element (code W), automatic or manual drains, gauge scales in MPa, psi or bar, and an external round gauge. Flow is published as curves rather than a single rated figure, so ask us to confirm sizing and datasheet figures for your application.
| Model | GFR300C15LF2T AirTAC Filter Regulator NPT 1/2 in |
|---|---|
| Series | GFR300 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR300 | G-series filter regulator, 300 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR300 · See datasheet · 40 µm |
|---|---|
| One size down | GFR200 |
| One size up | GFR400 |
| Add lubrication | GFC300-C1 (two-unit set) |
Feeding filtered, regulated air to the cylinder and air-tool circuit of a bench assembly cell, with the low-pressure regulator holding a reduced set pressure for light clamping work.
Conditioning air for the gripper and pusher cylinders on a bottling conveyor, where the 40 um element keeps particulate out of the valves and the differential drain clears collected water.
Supplying clean, regulated air to a low-pressure laboratory test rig or fixture-actuation panel, with the psi gauge giving a direct local reading at the rig.
Choose the size and port step (200/300/400/600, 1/8 to 1 in) against the air demand of the circuit; this unit sits at 300 with 1/2 in NPT ports. Pick the drain: differential-pressure (this model), automatic (A) or manual (M). Filter grade is 40 um standard, with 5 um (W) where finer filtration is needed. Gauge scales come in MPa, psi or bar; this one reads psi. Thread is NPT here, with PT and G available to order, and the bracket is included. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes GFR flow as curves rather than a single rated figure, so we do not quote a number here. Send us your application details and we will confirm the flow and full datasheet figures for this 300-size, 1/2 in NPT unit on request.
This model uses the differential-pressure drain, the standard option for the GFR series. Automatic (code A) and manual (code M) drain versions are available to order if your installation needs them.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.