The AirTAC GFR300C15LF2T AirTAC Filter Regulator NPT 1/2 in is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$47.48 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR300C15LF2T AirTAC Filter Regulator NPT 1/2 in

The AirTAC GFR300C15LF2T is a filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This 300-size unit has 1/2 in NPT ports, a 40 um filter element, a differential-pressure drain and a low-pressure regulator type, with an embedded square gauge reading in psi. The bowl is metal, a mounting bracket is included, and no reverse (check) valve is fitted. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing.

This is a genuine AirTAC part from the GFR series, which spans sizes 200, 300, 400 and 600 with port sizes from 1/8 to 1 in and PT, G or NPT threads. Other options include a 5 um element (code W), automatic or manual drains, gauge scales in MPa, psi or bar, and an external round gauge. Flow is published as curves rather than a single rated figure, so ask us to confirm sizing and datasheet figures for your application.

GFR300C15LF2T AirTAC Filter Regulator NPT 1/2 in Technical Specifications

ModelGFR300C15LF2T AirTAC Filter Regulator NPT 1/2 in
SeriesGFR300 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR300C15LF2T AirTAC Filter Regulator NPT 1/2 in

GFR300G-series filter regulator, 300 body — sets the port range.
C1Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR300 · See datasheet · 40 µm
One size downGFR200
One size upGFR400
Add lubricationGFC300-C1 (two-unit set)

Where the GFR300C15LF2T AirTAC Filter Regulator NPT 1/2 in Is Used

factory

Assembly-cell air preparation

Feeding filtered, regulated air to the cylinder and air-tool circuit of a bench assembly cell, with the low-pressure regulator holding a reduced set pressure for light clamping work.

conveyor_belt

Bottling-line gripper circuit

Conditioning air for the gripper and pusher cylinders on a bottling conveyor, where the 40 um element keeps particulate out of the valves and the differential drain clears collected water.

science

Laboratory test rig supply

Supplying clean, regulated air to a low-pressure laboratory test rig or fixture-actuation panel, with the psi gauge giving a direct local reading at the rig.

Is the GFR300C15LF2T AirTAC Filter Regulator NPT 1/2 in the Right Unit?

Choose the size and port step (200/300/400/600, 1/8 to 1 in) against the air demand of the circuit; this unit sits at 300 with 1/2 in NPT ports. Pick the drain: differential-pressure (this model), automatic (A) or manual (M). Filter grade is 40 um standard, with 5 um (W) where finer filtration is needed. Gauge scales come in MPa, psi or bar; this one reads psi. Thread is NPT here, with PT and G available to order, and the bracket is included. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR300C15LF2T AirTAC Filter Regulator NPT 1/2 in FAQ

AirTAC publishes GFR flow as curves rather than a single rated figure, so we do not quote a number here. Send us your application details and we will confirm the flow and full datasheet figures for this 300-size, 1/2 in NPT unit on request.

This model uses the differential-pressure drain, the standard option for the GFR series. Automatic (code A) and manual (code M) drain versions are available to order if your installation needs them.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR300C15LF2T AirTAC Filter Regulator NPT 1/2 in

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR300C15LF2T and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.