The AirTAC GFR300C15MJC2 AirTAC Filter Regulator PT1/2, 40 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR300C15MJC2 is an AirTAC GFR series filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This unit is built in size 300 with a PT1/2 (1/2 in) PT thread, a 40 um standard filter element, and a manual-drain polycarbonate bowl that you empty by hand on a maintenance schedule. Outlet pressure is set anywhere in the 0.05-0.9 MPa (7-130 psi) adjustment range, and the fitted round gauge reads in psi so the set point is visible at a glance. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing).
This is a genuine AirTAC part. The GFR series spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 in, and options include automatic, manual or differential-pressure drains, a 5 um element (code W), embedded square or external round gauges with MPa, psi or bar scales, a reverse/check valve, and G (BSPP) or NPT threads in place of the PT standard. Flow is published as curves rather than a single rated figure, so ask us to confirm sizing and datasheet figures for your application before you order.
| Model | GFR300C15MJC2 AirTAC Filter Regulator PT1/2, 40 um |
|---|---|
| Series | GFR300 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR300 | G-series filter regulator, 300 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR300 · See datasheet · 40 µm |
|---|---|
| One size down | GFR200 |
| One size up | GFR400 |
| Add lubrication | GFC300-C1 (two-unit set) |
Point-of-use filtration and pressure regulation for the air line feeding a pneumatic press cylinder, keeping the set pressure stable at the machine while the manual drain is bled during scheduled checks.
Conditioning the compressed air that drives clamp and push cylinders on a packaging conveyor line, with the psi gauge letting line staff verify the regulator setting at a glance.
Filtering and regulating shop air ahead of pneumatic tooling and workholding on a CNC cell, where a 1/2 in PT connection matches the machine's main air inlet.
Size 300 with a 1/2 in PT port suits circuits plumbed at that size; step up to size 400 or 600, or down to 200, if your piping or air demand differs. Drain type is a real choice: this code has a manual drain, best where an operator can bleed the bowl on a routine schedule - automatic and differential-pressure drains are available on other codes if unattended water removal matters. The 40 um element is the standard grade; specify the W option for 5 um where finer filtration is required. The fitted round gauge reads psi; an embedded square gauge and MPa or bar scales are alternatives. Thread is PT as standard - order G (BSPP) or NPT to match your piping, and note this code is supplied without a mounting bracket. Flow is published as curves, not a single rating, so send us your flow requirement and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so there is no one l/min or SCFM number we can honestly quote. Tell us your required flow and operating pressure and we will confirm sizing against the datasheet on request before you order.
The M in the code means the bowl drain is opened by hand to expel collected water and dirt. That suits installations where an operator walks the line on a fixed maintenance schedule. If the unit will sit unattended, the same family is available with an automatic drain (code A) or a differential-pressure drain (blank) instead.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.