The AirTAC GFR300C15MLJC2TK AirTAC Filter Regulator NPT1/2 is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR300C15MLJC2TK is an AirTAC GFR300 filter regulator: water and particulate filtration plus pressure regulation in a single body. Compressed air passes a 40 um element, then a low-pressure regulator sets the downstream pressure. This configuration has a 1/2 in NPT port, a metal bowl with manual drain, a round gauge reading in psi, and a reverse/check valve fitted. No mounting bracket is included. Maximum inlet pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C, non-freezing.
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 in, drain choices (differential-pressure, automatic or manual), 40 um standard or 5 um (W) filtration, gauge and thread options. Rated flow is published as curves rather than a single figure, so ask us to confirm sizing and datasheet figures for your application before ordering.
| Model | GFR300C15MLJC2TK AirTAC Filter Regulator NPT1/2 |
|---|---|
| Series | GFR300 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR300 | G-series filter regulator, 300 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR300 · See datasheet · 40 µm |
|---|---|
| One size down | GFR200 |
| One size up | GFR400 |
| Add lubrication | GFC300-C1 (two-unit set) |
Conditions and regulates the air feeding a small pneumatic press, where the operator sets line pressure by hand and reads it on the fitted psi gauge.
Feeds carton sealers and case packers that need water and dirt removed upstream and a steady, manually adjustable supply pressure at each machine.
Point-of-use conditioning for spray guns and coating applicators, with the manual drain used for a bowl purge at the end of each shift.
Size and port set the flow path: this unit is size 300 with a 1/2 in NPT port, and you can step to size 200, 400 or 600 when the line needs a different port. Drain type is a real choice: manual (as coded here) needs periodic draining, while automatic or differential-pressure drains suit unattended installations. Element grade is 40 um standard; specify W for 5 um where finer filtration matters. Gauge scale (MPa, psi or bar) and thread (PT standard, with G or NPT as order options) are selectable, as is a mounting bracket. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR300 as curves rather than a single rated figure, so we do not quote a number here. Send us your line pressure and air demand and we will confirm sizing from the datasheet on request.
The M in the code specifies a manual drain: someone opens the bowl drain periodically. If the unit sits in an unattended spot, the same size is available with automatic or differential-pressure draining - tell us and we will quote the variant.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.