verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR400 · Filter Regulator (filter + regulator in one body)

GFR400C15AJF2G AirTAC Filter Regulator G1/2

The AirTAC GFR400C15AJF2G AirTAC Filter Regulator G1/2 is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$79.39 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR400C15AJF2G AirTAC Filter Regulator G1/2

The AirTAC GFR400C15AJF2G is a size 400 filter regulator: water and particulate filtration plus pressure regulation combined in one body, with a 1/2 in G-thread port. This configuration carries an automatic drain that ejects collected condensate without manual attention, a 40 um standard filter element, and the standard regulator with an adjustment range of 0.15-0.9 MPa (20-130 psi). An embedded square gauge graduated in psi is fitted, and no mounting bracket is included with this code. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. The 400-size bowl is polycarbonate (PC).

This is a genuine AirTAC part. The GFR filter-regulator line spans sizes 200, 300, 400 and 600, with options including a 5 um element (code W), manual or differential-pressure drain, G or NPT thread, gauge scales in MPa, psi or bar, and a mounting bracket. Flow figures are published as curves rather than a single rating, so ask us to confirm sizing against your application - we will provide the datasheet on request.

GFR400C15AJF2G AirTAC Filter Regulator G1/2 Technical Specifications

ModelGFR400C15AJF2G AirTAC Filter Regulator G1/2
SeriesGFR400 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR400C15AJF2G AirTAC Filter Regulator G1/2

GFR400G-series filter regulator, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR400 · See datasheet · 40 µm
One size downGFR300
One size upGFR600
Add lubricationGFC400-C1 (two-unit set)

Where the GFR400C15AJF2G AirTAC Filter Regulator G1/2 Is Used

precision_manufacturing

CNC machining centre air supply

Point-of-use conditioning on the 1/2 in air drop feeding a CNC machining centre: the 40 um element and automatic drain keep condensate and swarf-laden moisture out of the machine's solenoid valves and air cylinders, while the regulator holds a steady set pressure for clamping and tool-change actuation.

factory

Packaging line actuator feed

Mounted at the header take-off of a bottling or cartoning line, the GFR400C15AJF2G filters and regulates the supply to case-packing and sealing cylinders. The automatic drain handles condensate on a line that runs unattended across shifts, and the psi gauge lets technicians verify set pressure at a glance.

handyman

Maintenance workshop ring main

Installed on the 1/2 in branch of a plant maintenance workshop's compressed-air ring main, this filter regulator conditions the supply for impact wrenches, air ratchets and blow-off stations. The square psi gauge supports quick pressure checks, and the 40 um element protects general-purpose tools from water and pipe scale.

Is the GFR400C15AJF2G AirTAC Filter Regulator G1/2 the Right Unit?

Choose the size and port step against the air demand of the circuit: this unit is size 400 with a 1/2 in port, one step up from the 300 series for higher-demand lines. Drain type is a real decision: automatic (this code) suits unattended or hard-to-reach installations, manual suits attended daily checks, and the differential-pressure default (blank) drains on a pressure drop. The 40 um element is standard; specify the W code if the downstream equipment needs 5 um filtration. Gauge scale is psi on this unit, with MPa and bar available as alternatives. PT is the standard thread; G (BSPP) and NPT are catalogue options to order - state the thread your pipework needs when ordering. This code (J) ships the unit without a mounting bracket; add the bracket option if you want panel or wall fixing.

Flow for the GFR400 is published as curves, not a single rated figure, so we cannot quote one number honestly. Tell us your application and we will confirm sizing against the datasheet curves before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR400C15AJF2G AirTAC Filter Regulator G1/2 FAQ

AirTAC publishes flow for the GFR400 as performance curves rather than a single rated figure, so we do not quote one number out of context. Send us your application details - inlet pressure, set pressure and the air demand of the equipment - and we will confirm the sizing against the datasheet curves and provide the datasheet on request.

The A in the code GFR400C15AJF2G means the bowl drain ejects collected condensate automatically, with no manual intervention. It is the right choice for unattended installations, elevated mounting positions or any site where daily manual draining is impractical. The same GFR400 body is also available with a manual drain (code M) or the differential-pressure default (blank) if your maintenance routine suits those instead.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR400C15AJF2G AirTAC Filter Regulator G1/2

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR400C15AJF2G and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.