verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR400 · Filter Regulator (filter + regulator in one body)

GFR400C15AJF2WGK AirTAC Filter Regulator G1/2, 5 um

The AirTAC GFR400C15AJF2WGK AirTAC Filter Regulator G1/2, 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$90.79 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR400C15AJF2WGK AirTAC Filter Regulator G1/2, 5 um

The GFR400C15AJF2WGK is an AirTAC GFR-series filter regulator: water and particulate filtration plus downstream pressure regulation combined in a single body. This configuration is built around a G1/2 port, a 5 um filter element (the finer of the two grades offered on this series), an automatic drain that expels collected condensate from the polycarbonate bowl without operator attention, an embedded square gauge reading in psi, and a reverse (check) valve fitted in the code. Maximum inlet pressure is 1.0 MPa (145 psi), the standard regulator covers 0.15-0.9 MPa (20-130 psi), and the working temperature range is -5 to 70 C (non-freezing). No mounting bracket is included with this code.

This is a genuine AirTAC part. The GFR series spans four sizes (200, 300, 400 and 600) with ports from 1/8 to 1 in, and can be ordered with manual or differential-pressure draining, the 40 um standard element, alternative gauge scales (MPa, psi or bar), an external round gauge, and PT or NPT threads in place of G. AirTAC publishes flow as curves rather than a single rated figure, so ask us to confirm the datasheet figures for your application before ordering.

GFR400C15AJF2WGK AirTAC Filter Regulator G1/2, 5 um Technical Specifications

ModelGFR400C15AJF2WGK AirTAC Filter Regulator G1/2, 5 um
SeriesGFR400 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR400C15AJF2WGK AirTAC Filter Regulator G1/2, 5 um

GFR400G-series filter regulator, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR400 · See datasheet · 40 µm
One size downGFR300
One size upGFR600
Add lubricationGFC400-C1 (two-unit set)

Where the GFR400C15AJF2WGK AirTAC Filter Regulator G1/2, 5 um Is Used

precision_manufacturing

Robotic pick-and-place cells

Filtered, regulated supply air feeding gripper circuits on an assembly robot, where the 5 um element protects fine-orifice components and the integral check valve suits circuits where reverse flow must be prevented.

conveyor_belt

Bottling-line conveyor drives

Regulated air to the cylinders that index, stop and divert containers on a filling line, with the automatic drain expelling bowl condensate over continuous shifts without an operator round.

build

Automotive assembly tool stations

A point-of-use filter regulator ahead of air tools and clamping fixtures at a workshop bench, with the psi-scale square gauge letting operators set and read tool supply pressure directly.

Is the GFR400C15AJF2WGK AirTAC Filter Regulator G1/2, 5 um the Right Unit?

Size and port are the first decisions: the GFR series steps through 200, 300, 400 and 600, and the larger the size the larger the port and the greater the flow capacity - match the step to your air demand and existing piping (this unit is size 400 with a G1/2 port). Drain choice matters in service: automatic draining (this unit) suits unattended installations, manual draining puts an operator in the loop, and the differential-pressure default drains in response to pressure drop - note that the manual-drain version also lowers the regulation floor to 0.05 MPa (7 psi) versus 0.15 MPa (20 psi) here. Choose the 5 um element (this unit) when downstream equipment needs finer air than the 40 um standard grade. Gauge scale (MPa, psi or bar), thread (PT standard, G or NPT to order) and bracket are all selectable. Because AirTAC publishes flow only as curves rather than a single rating, send us your flow requirement and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR400C15AJF2WGK AirTAC Filter Regulator G1/2, 5 um FAQ

AirTAC publishes GFR flow as performance curves rather than a single rated figure, so we do not quote one number. Tell us your flow demand and line pressure and we will confirm the sizing from the datasheet on request.

Code A specifies an automatic drain, which expels condensate from the bowl without operator attention. On this series the automatic and differential-pressure drain versions regulate from 0.15 MPa (20 psi) upward, while the manual-drain version lowers the floor to 0.05 MPa (7 psi). All versions regulate up to 0.9 MPa (130 psi).

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR400C15AJF2WGK AirTAC Filter Regulator G1/2, 5 um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR400C15AJF2WGK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.