The AirTAC GFR400C15ALC3TK AirTAC Filter Regulator NPT1/2 Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR400 series combines water and particulate filtration with pressure regulation in a single body. This configuration is built with a 1/2 in NPT port, an automatic drain that clears collected condensate without manual attention, a 40 um standard filter element, a low-pressure regulator for circuits that need a setting range below the standard type, an external round gauge scaled in bar, and a reverse (check) valve fitted. The drain bowl on this unit is metal, and a mounting bracket is included.
This is a genuine AirTAC part. The GFR family is offered in sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in, a choice of automatic, manual or differential-pressure drains, 40 um standard or 5 um (W) elements, gauge scales in MPa, psi or bar, and G (BSPP) or NPT thread options. Maximum working pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rating, so ask us to confirm the datasheet figures for your application.
| Model | GFR400C15ALC3TK AirTAC Filter Regulator NPT1/2 Low-Pressure |
|---|---|
| Series | GFR400 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR400 | G-series filter regulator, 400 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR400 · See datasheet · 40 µm |
|---|---|
| One size down | GFR300 |
| One size up | GFR600 |
| Add lubrication | GFC400-C1 (two-unit set) |
Filtered, regulated air for the seal, clamp and push cylinders on a carton or shrink-wrap line, with the automatic drain clearing condensate through continuous shifts.
Supplies clean, pressure-controlled air to workholding clamps on a machining cell, with the fitted check valve blocking reverse flow in the circuit.
Suits atomizing air on a paint or coating booth where the regulator must set a lower pressure than a standard unit; the 40 um element keeps the supply line free of particulate.
Size and port step up together across the GFR range (200/300/400/600, 1/8 in to 1 in), so choose the size whose flow curve covers your demand rather than the port alone. Drain choices are automatic (this unit), manual, or the differential-pressure default; automatic suits unattended duty. Filter grade is 40 um standard; specify W for the 5 um element where finer particulate matters. An embedded square gauge is standard and an external round gauge is optional, scaled in MPa, psi or bar - this unit carries the round bar gauge. Thread is PT as standard with G (BSPP) and NPT as order options; this unit is NPT. Flow is published as curves, not a single rated figure, so send us your application conditions and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves, not as a single rated figure, so we do not quote a number here. Send us your line pressure and air demand and we will confirm the flow figures from the datasheet for this exact model before you order.
This model carries code A, an automatic drain that ejects collected condensate without operator attention. The GFR family is also available with a manual drain or with the differential-pressure drain as the default; tell us which suits your duty and we will quote the matching code.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.