The AirTAC GFR400C15ALNTK AirTAC Filter Regulator NPT1/2 is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR400C15ALNTK is a size 400 filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This configuration carries a 1/2 in NPT port, an automatic drain that ejects collected condensate without manual attention, and the standard 40 um filter element. It is the low-pressure type, is supplied with a mounting bracket, and has a reverse/check valve fitted. No gauge is fitted on this variant. Maximum working (inlet) pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C (non-freezing). The bowl on this size 400 unit is PC (polycarbonate).
This is a genuine AirTAC part. The GFR family is published in sizes 200, 300, 400 and 600, with port options, drain types, filter grades, gauge choices and thread variants across the range. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing figures for your application on request.
| Model | GFR400C15ALNTK AirTAC Filter Regulator NPT1/2 |
|---|---|
| Series | GFR400 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR400 | G-series filter regulator, 400 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR400 · See datasheet · 40 µm |
|---|---|
| One size down | GFR300 |
| One size up | GFR600 |
| Add lubrication | GFC400-C1 (two-unit set) |
Feeding filtered, regulated air to a bench or gap-frame pneumatic press on a production line, where the automatic drain keeps condensate out of the valve stack between shifts.
Supplying the cylinders and diverters on a carton or case conveyor system, with the low-pressure regulator set to the actuation pressure the machine builder specifies.
A point-of-use filter regulator at the air drop feeding an assembly cell, protecting downstream directional valves and cylinders from water and pipe-scale carryover.
Step up or down through the GFR sizes (200/300/400/600) to match the port and flow path your line needs; this unit is the size 400 step with a 1/2 in port. Choose the drain to suit the installation: automatic (this model) for unattended condensate rejection, manual for periodic service, or the differential-pressure default. Filter grade is 40 um standard; specify the W code for the 5 um element where finer filtration is required. Gauge options (square or round, MPa/psi/bar scales) can be selected on variants that carry them - this code has none fitted. Thread is NPT here; PT is the standard and G (BSPP) is also a catalogue option. Bracket included on this code. Because flow is published as curves and not a single rating, send us your application details and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves, not as a single rated number, so we do not quote a figure here. Send us your line pressure, downstream demand and port size and we will confirm the flow and datasheet figures for this exact model on request.
In the code GFR400C15ALNTK, the A position selects the automatic drain, which rejects collected condensate without manual intervention, and the N position means no gauge is fitted. If you need a local pressure indication, other GFR variants carry an embedded square gauge or an optional external round gauge in MPa, psi or bar scales - ask us to quote the right code.