verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR400 · Filter Regulator (filter + regulator in one body)

GFR400C15LC2 AirTAC Filter Regulator PT1/2 Low-Pressure

The AirTAC GFR400C15LC2 AirTAC Filter Regulator PT1/2 Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$69.94 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR400C15LC2 AirTAC Filter Regulator PT1/2 Low-Pressure

The GFR400C15LC2 is an AirTAC GFR400 filter regulator: filtration and pressure regulation combined in a single body. Compressed air passes through a 40 um element that strips out water and particulate, then through a low-pressure-type regulator, with the downstream pressure shown on the round psi gauge fitted to this configuration. The 1/2 in PT port suits main air drops and larger machine supplies, the differential-pressure drain bleeds collected condensate automatically as flow passes through, and the polycarbonate bowl lets you see the liquid level at a glance. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing.

This is a genuine AirTAC part. The GFR series is available in sizes 200, 300, 400 and 600 with port sizes from 1/8 to 1 in, and with choices of drain type, 40 um or 5 um filtration, gauge style and scale, PT, G or NPT thread, and bracket or no bracket. Because AirTAC publishes flow only as curves rather than a single rated figure, we confirm the datasheet and flow figures for your application on request.

GFR400C15LC2 AirTAC Filter Regulator PT1/2 Low-Pressure Technical Specifications

ModelGFR400C15LC2 AirTAC Filter Regulator PT1/2 Low-Pressure
SeriesGFR400 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR400C15LC2 AirTAC Filter Regulator PT1/2 Low-Pressure

GFR400G-series filter regulator, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR400 · See datasheet · 40 µm
One size downGFR300
One size upGFR600
Add lubricationGFC400-C1 (two-unit set)

Where the GFR400C15LC2 AirTAC Filter Regulator PT1/2 Low-Pressure Is Used

factory

Packaging line main air drop

Feeding a packaging machine's valve island and cylinders from a 1/2 in main drop: the 40 um element keeps line debris and condensed water out of the valves while the low-pressure-type regulator holds a gentle, stable supply pressure for delicate sealing and forming actuation.

precision_manufacturing

Pneumatic clamping on a CNC fixture

Supplying clamping cylinders on a machining-centre fixture, where the regulator sets a repeatable low clamp pressure and the round psi gauge gives the operator a visible reference, while filtered air protects the clamping valves from water and swarf-carrying compressed air.

conveyor_belt

Conveyor divertor and stopper actuators

Air prep for the divertors, stoppers and pop-up rollers on a sortation conveyor: the filter-regulator cleans and tames the supply at the point of use, the differential-pressure drain handles condensate without operator attention, and the 1/2 in port carries the volume those actuators draw.

Is the GFR400C15LC2 AirTAC Filter Regulator PT1/2 Low-Pressure the Right Unit?

Start with the size and port: 400 is the larger step in the GFR range, and this unit's PT1/2 (1/2 in) port matches heavier machine supplies - step up or down only if your line flow demands it. Next, pick the drain: this unit uses the differential-pressure drain (the default), which discharges condensate automatically as air flows through; a manual-drain or automatic-drain version can be ordered if your duty cycle suits those better. Filtration here is the standard 40 um grade - choose the 5 um (W) option only where downstream equipment needs finer particles removed. The gauge on this unit is the external round type with a psi scale; an embedded square gauge and MPa or bar scales are the other catalogue choices. Thread is PT as standard, with G (BSPP) and NPT available as order options, and the mounting bracket is included. Finally, the honest routing: AirTAC publishes flow as curves, not a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR400C15LC2 AirTAC Filter Regulator PT1/2 Low-Pressure FAQ

AirTAC publishes flow for the GFR400 series as curves rather than a single rated figure, so we do not quote a rated flow, Cv or SCFM number. Tell us your application and required flow, and we will confirm the figures from the datasheet on request before you order.

The L in the code marks this as the low-pressure-type regulator variant rather than the standard type, and C2 specifies the external round gauge fitted with a psi scale (MPa and bar scales are the other catalogue options). The exact adjustment range for the low-pressure type is not published in the materials at hand, so we confirm it on request. The unit also carries the standard 40 um filter element and the differential-pressure drain.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR400C15LC2 AirTAC Filter Regulator PT1/2 Low-Pressure

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR400C15LC2 and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.