verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR400 · Filter Regulator (filter + regulator in one body)

GFR400C15LC3WTK AirTAC Filter Regulator NPT1/2 5 um

The AirTAC GFR400C15LC3WTK AirTAC Filter Regulator NPT1/2 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$81.96 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR400C15LC3WTK AirTAC Filter Regulator NPT1/2 5 um

The AirTAC GFR400C15LC3WTK is a size 400 filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in one body. This configuration carries a 1/2 in NPT port, a 5 um filter element (code W), a differential-pressure drain, a fitted round gauge with bar scale, an integrated reverse/check valve, and a mounting bracket. It is the low-pressure regulator type, intended for circuits that hold a lower set pressure than a standard unit.

This is a genuine AirTAC part. The GFR series spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, and is offered with a choice of drain type, filter grade, gauge style and scale, thread form and bracket. Flow is published as curves rather than a single rated figure, so we confirm the datasheet and sizing figures on request.

GFR400C15LC3WTK AirTAC Filter Regulator NPT1/2 5 um Technical Specifications

ModelGFR400C15LC3WTK AirTAC Filter Regulator NPT1/2 5 um
SeriesGFR400 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR400C15LC3WTK AirTAC Filter Regulator NPT1/2 5 um

GFR400G-series filter regulator, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR400 · See datasheet · 40 µm
One size downGFR300
One size upGFR600
Add lubricationGFC400-C1 (two-unit set)

Where the GFR400C15LC3WTK AirTAC Filter Regulator NPT1/2 5 um Is Used

precision_manufacturing

Pneumatic clamping on a machining fixture

Filtered, low-pressure regulated air holds workpieces in a clamping fixture on a CNC machining line, with the check valve helping hold the set circuit while the element strips water and swarf carryover.

conveyor_belt

Carton-forming packaging machine supply

A single point-of-use filter regulator feeding the cylinders and actuators on a carton erecting and sealing conveyor, keeping the machine's air clean and the circuit held at the set pressure.

factory

Spray booth air preparation

Conditioning the air line to paint spray guns in a finishing booth: the 5 um element reduces water and particulate reaching the gun while the regulator holds the gun supply at the set pressure.

Is the GFR400C15LC3WTK AirTAC Filter Regulator NPT1/2 5 um the Right Unit?

Work from the port step first: size 400 with a 1/2 in port sits in the middle of the GFR range (200/300/400/600), so step up to 600 if your line may grow, or down to 300 for compact drops. Drain type is a real choice: this unit uses the differential-pressure drain (default); automatic (A) or manual (M) drains can be specified instead. Filter grade is 5 um here (code W) against the 40 um standard element - pick 5 um where downstream valves or instruments are sensitive. The round gauge with bar scale is fitted; the embedded square gauge is the standard alternative, with MPa, psi or bar scales. Thread is NPT on this code; PT is the standard thread and G (BSPP) is also an order option. A bracket is included and the K code adds a reverse/check valve.

Because flow is published as curves rather than a single rating, ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR400C15LC3WTK AirTAC Filter Regulator NPT1/2 5 um FAQ

AirTAC publishes G-series flow as curves, not as a single rated figure, so there is no one number we can honestly quote. Send us your line pressure, set pressure and expected air demand and we will confirm the sizing from the datasheet curves on request before you order.

The W code in the model number selects the 5 um filter element in place of the 40 um standard. Choose 5 um where downstream valves, instruments or spray equipment are sensitive to finer particulate and water carryover; the 40 um element remains the standard choice for general plant air. Both grades are available across the GFR range.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR400C15LC3WTK AirTAC Filter Regulator NPT1/2 5 um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR400C15LC3WTK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.