verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR400 · Filter Regulator (filter + regulator in one body)

GFR400C15MC3T AirTAC Filter Regulator NPT1/2

The AirTAC GFR400C15MC3T AirTAC Filter Regulator NPT1/2 is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$70.56 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR400C15MC3T AirTAC Filter Regulator NPT1/2

The GFR400C15MC3T is an AirTAC GFR400 filter regulator: one body that strips water and particulate from compressed air and holds downstream pressure steady. This configuration is threaded NPT1/2, carries the standard 40 um filter element, and drains collected condensate by hand through the manual drain, so it suits lines where an operator can bleed the bowl during routine checks. Outlet pressure is set anywhere in the 0.05-0.9 MPa (7-130 psi) range and read on the fitted round gauge with bar scale; the polycarbonate bowl is rated with the unit for -5 to 70 C (non-freezing) and a maximum inlet pressure of 1.0 MPa (145 psi).

This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 in, and options include a 5 um element (code W), automatic or differential-pressure drain, square or round gauges with MPa, psi or bar scales, G (BSPP) or NPT threads in place of the PT standard, and bracket or no-bracket mounting. Flow for this series is published as curves rather than a single rating, so ask us to confirm the datasheet figures against your application.

GFR400C15MC3T AirTAC Filter Regulator NPT1/2 Technical Specifications

ModelGFR400C15MC3T AirTAC Filter Regulator NPT1/2
SeriesGFR400 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR400C15MC3T AirTAC Filter Regulator NPT1/2

GFR400G-series filter regulator, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR400 · See datasheet · 40 µm
One size downGFR300
One size upGFR600
Add lubricationGFC400-C1 (two-unit set)

Where the GFR400C15MC3T AirTAC Filter Regulator NPT1/2 Is Used

factory

Automotive paint booth drops

Point-of-use conditioning at each paint line drop: water and pipe scale are stripped from shop air before the spray gun, and gun pressure is set and held on the bar gauge between coats, with the bowl bled at shift start.

conveyor_belt

Cartoning machine cylinder bank

Feeding the fold and press cylinders on a packaging conveyor line: clean, regulated air keeps box-forming strokes consistent through the run, with the manual drain opened during the operator's start-up checks.

science

Laboratory instrument air feed

Conditioning the compressed-air supply to analyzers and pneumatic actuators in a lab: the 40 um element guards sensitive instruments while the regulator trims the supply pressure to the level the equipment specifies.

Is the GFR400C15MC3T AirTAC Filter Regulator NPT1/2 the Right Unit?

Size 400 with a 1/2 in port sits in the upper-middle of the GFR range; step down to 300 or up to 600 depending on the air demand of your line, and we can check the published flow curves against your requirement before you order. This unit drains manually, which is simple and dependable where staff are on site; choose the automatic drain (code A) for unattended installations or the differential-pressure default where it fits the duty. The 40 um element is the standard grade; specify 5 um (code W) for finer protection of downstream equipment. The fitted round gauge reads in bar, with square gauges and MPa or psi scales available as alternatives, and G (BSPP) or NPT threads can be ordered instead of the PT standard. A bracket is included for mounting.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR400C15MC3T AirTAC Filter Regulator NPT1/2 FAQ

AirTAC publishes flow for the GFR400 as curves, not as a single rated figure, so we do not quote a number here. Send us your line pressure and air demand and we will confirm the datasheet flow figures for this 1/2 in unit before you order.

The M in the code is the manual drain: an operator opens it to bleed collected condensate, which suits attended lines with routine checks. If the unit will run unattended, order the same filter regulator with the automatic drain (code A) or the differential-pressure default instead.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR400C15MC3T AirTAC Filter Regulator NPT1/2

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR400C15MC3T and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.