The AirTAC GFR400C15MJF1WT AirTAC Filter Regulator NPT1/2 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR400C15MJF1WT is a size 400 filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in one body. This configuration carries a 1/2 in NPT port, a 5 um filter element (the finer of the two catalogue grades), a manual drain on the bowl, an embedded square pressure gauge scaled in MPa, and the standard regulator type. The regulation range with manual drain is 0.05-0.9 MPa (7-130 psi), maximum inlet pressure is 1.0 MPa (145 psi), and the operating temperature range is -5 to 70 C (non-freezing). No mounting bracket is included and no reverse/check valve is fitted.
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, a choice of 40 um standard or 5 um (W) elements, manual, automatic or differential-pressure drains, square or round gauges with MPa, psi or bar scales, and PT, G or NPT threads. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet figures for your application before ordering.
| Model | GFR400C15MJF1WT AirTAC Filter Regulator NPT1/2 5 um |
|---|---|
| Series | GFR400 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR400 | G-series filter regulator, 400 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR400 · See datasheet · 40 µm |
|---|---|
| One size down | GFR300 |
| One size up | GFR600 |
| Add lubrication | GFC400-C1 (two-unit set) |
Feeds filtered, regulated air to the tool-change and clamping circuits of a CNC machining centre, with the 5 um element protecting directional valves from particulate and the manual drain cleared during shift start-up.
Sits at the drop of a packaging line's air header to condition and set pressure for carton-forming and sealing cylinders, with the square MPa gauge giving operators a local setpoint reference.
Mounted in a machine's pneumatic control panel to filter and regulate one branch of the distribution system independently, keeping the branch setpoint stable while the main header runs at full line pressure.
Start with the port and size step: this unit is size 400 with a 1/2 in NPT port, one step up from size 300 (1/2 in is also available in size 300), so match the size to the flow your line needs and ask us to check the curve. Choose the drain: this unit has a manual drain, which you bleed by hand; automatic and differential-pressure drains are available in the family if you cannot schedule manual blowdowns. Choose the element grade: 40 um is the standard grade and 5 um (code W, fitted here) suits finer downstream needs. Gauge options are the embedded square gauge (fitted here, MPa scale) or an external round gauge, with MPa, psi or bar scales. Thread is NPT here; PT is the standard catalogue thread and G (BSPP) is also orderable. Bracket options apply per the code (none on this unit).
One honest note on sizing: AirTAC publishes flow as curves, not as a single rated number, so we do not quote a flow figure here. Send us your application details and we will confirm the sizing against the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for this series as curves rather than a single rated figure, so we do not quote a flow number on the page. Tell us your application and we will confirm the sizing from the datasheet on request before you order.
The M in the code specifies a manual drain: condensate collected in the bowl is released by hand. Choose manual where the machine is attended and blowdowns can be scheduled; automatic or differential-pressure drains are available in the GFR family for unattended duty. Note that with a manual drain the regulation range is 0.05-0.9 MPa (7-130 psi).
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.