The AirTAC GFR400C15MJF3TK AirTAC Filter Regulator NPT1/2 is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR400C15MJF3TK is an AirTAC GFR400 filter regulator: one body that removes water and particulate from compressed air and regulates downstream pressure. This configuration carries a 1/2 in NPT port, the 40 um standard filter element, a manual drain on the bowl, an embedded square gauge scaled in bar, and a built-in reverse (check) valve; it is supplied without a mounting bracket. Maximum inlet pressure is 1.0 MPa (145 psi) and the regulator adjusts from 0.05 to 0.9 MPa (7-130 psi). Operating temperature is -5 to 70 C, non-freezing.
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 in, a choice of differential-pressure, automatic or manual drains, 40 um standard or 5 um (W) filtration, gauge scales in MPa, psi or bar, and PT, G or NPT threads. Flow for this series is published as curves rather than a single rating, so ask us to confirm the datasheet figures for your application.
| Model | GFR400C15MJF3TK AirTAC Filter Regulator NPT1/2 |
|---|---|
| Series | GFR400 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR400 | G-series filter regulator, 400 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR400 · See datasheet · 40 µm |
|---|---|
| One size down | GFR300 |
| One size up | GFR600 |
| Add lubrication | GFC400-C1 (two-unit set) |
Clean, regulated air for a directional control valve stack on an automated machine, so spools and seals see dry air at a set pressure.
Air preparation for the pick-and-place and clamp cylinders on a conveyor or cartoning line, with the check valve holding the downstream circuit.
A filtered, regulated supply point at a production workstation where operators run air tools or small actuators from the main plant line.
Pick the size by port and required flow: this unit is size 400 with a 1/2 in NPT port. Drain is manual on this code - you open the drain by hand at intervals; automatic and differential-pressure drains are available on other codes in the family. Filtration is the 40 um standard element; the 5 um grade is code W. The gauge is the embedded square type with a bar scale; MPa and psi scales and an external round gauge are options. Thread is NPT here; PT is the standard thread and G (BSPP) is also orderable. The J suffix means no mounting bracket is included. Because flow is published as curves rather than a single rated figure, ask us to check the datasheet against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves, not as a single rated number, so we do not quote a figure. Tell us your application and we will confirm the datasheet flow figures and sizing on request before you order.
The M code gives the bowl a manual drain: collected water and particulate are released by opening the drain by hand at intervals you set. If you prefer unattended condensate removal, the family also offers automatic (A) and differential-pressure (blank) drains on other codes.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.