The AirTAC GFR400C15MLC2W AirTAC Filter Regulator PT1/2, 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR400C15MLC2W is an AirTAC GFR-series filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This size 400 unit carries a PT1/2 (1/2 in) PT-threaded port, a 5 um filter element (code W), a manual drain on the metal bowl, the low-pressure regulator type, and a round pressure gauge scaled in psi. A mounting bracket is included and no reverse/check valve is fitted. Maximum working (inlet) pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C (non-freezing).
This is a genuine AirTAC part. The GFR family is published in sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, plus drain, filter-grade, gauge, thread and bracket options across the range. Flow is published as curves rather than a single rated figure, so ask us to confirm sizing and the full datasheet for your application before ordering.
| Model | GFR400C15MLC2W AirTAC Filter Regulator PT1/2, 5 um |
|---|---|
| Series | GFR400 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR400 | G-series filter regulator, 400 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR400 · See datasheet · 40 µm |
|---|---|
| One size down | GFR300 |
| One size up | GFR600 |
| Add lubrication | GFC400-C1 (two-unit set) |
Filtering and regulating the supply to pneumatic clamps on a robotic welding cell, where clamps need clean air held at a reduced, stable setting.
Conditioning air ahead of spray guns or coating heads on a paint line: the 5 um element strips water and particulate before the air reaches the gun.
Supplying filtered, regulated air to cylinder-driven carton sealers, labelers and case packers along a packaging conveyor line.
Size 400 with a PT1/2 port suits circuits plumbed at 1/2 in; the family steps through sizes 200 to 600 as your flow path demands, and we will confirm flow against the published curves on request. Drain type is a real choice: this unit is manual (code M) for draining by hand at service intervals, while automatic and differential-pressure drains are catalogue alternatives. Filter grade is the 5 um element (W) here versus the 40 um standard. The gauge is the external round type scaled in psi; embedded square gauges and MPa or bar scales are catalogue options. Thread is PT as standard, with G (BSPP) and NPT available to order, and a mounting bracket is included.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves, not as a single rated figure, so we do not quote a number here. Tell us your application and we will confirm the flow and the full datasheet figures for this model on request.
This unit is coded M for a manual drain: the metal bowl is drained by hand at service intervals. The catalogue also lists automatic and differential-pressure drains on GFR units, and the 40 um standard element as well as the 5 um (W) grade fitted here, so an alternative configuration can be ordered.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.