verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR400 · Filter Regulator (filter + regulator in one body)

GFR400C15MLJC2T AirTAC Filter Regulator NPT1/2

The AirTAC GFR400C15MLJC2T AirTAC Filter Regulator NPT1/2 is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$69.01 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR400C15MLJC2T AirTAC Filter Regulator NPT1/2

The AirTAC GFR400C15MLJC2T is a GFR-series filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This size 400 unit is threaded NPT1/2, carries the standard 40 um filter element, and drains condensate manually. It is the low-pressure type and comes with the external round gauge fitted on a psi scale. Maximum inlet pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C, non-freezing. The polycarbonate bowl lets you see the condensate level at a glance.

This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 inch, plus options for automatic or differential-pressure drains, a 5 um element (code W), square or round gauges in MPa, psi or bar scales, and G or NPT threads in place of the PT standard. Flow is published as curves rather than a single rating, so ask us to confirm the datasheet figures for your application.

GFR400C15MLJC2T AirTAC Filter Regulator NPT1/2 Technical Specifications

ModelGFR400C15MLJC2T AirTAC Filter Regulator NPT1/2
SeriesGFR400 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR400C15MLJC2T AirTAC Filter Regulator NPT1/2

GFR400G-series filter regulator, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR400 · See datasheet · 40 µm
One size downGFR300
One size upGFR600
Add lubricationGFC400-C1 (two-unit set)

Where the GFR400C15MLJC2T AirTAC Filter Regulator NPT1/2 Is Used

valve

Pneumatic press feed

Filter and step the supply pressure down before a pneumatic press or clamp cylinder, with the psi round gauge giving the operator a direct reading at the setpoint.

factory

Packaging machine air supply

Condition the air feeding a packaging line's valves and actuators: the 40 um element catches pipe scale and rust while the manual drain clears accumulated water during changeovers.

science

Test-bench air loop

On a laboratory or test-bench air loop, the low-pressure regulator holds a gentle supply for sensitive instruments while the bowl strips water before it reaches them.

Is the GFR400C15MLJC2T AirTAC Filter Regulator NPT1/2 the Right Unit?

Size 400 with a 1/2 inch port sits in the upper-middle of the GFR range; step down to 300 or 200, or up to 600, as your air demand requires - flow is published as curves rather than a single rating, so ask us to confirm sizing against your application before ordering. This code is the low-pressure type (L); its exact adjustment range is not published, so confirm it with us if your setpoint is critical. The 40 um element is the standard grade; code W gives a 5 um element where finer filtration is needed.

Code M sets a manual drain, so plan to bleed the bowl by hand; the automatic (A) and differential-pressure (blank) drain codes remove that task. The C2 gauge option fits the external round gauge reading in psi; the embedded square gauge in MPa, psi or bar scales comes on other codes. This unit is threaded NPT (T); PT is the AirTAC standard and G (BSPP) is also an order option. Code J means no mounting bracket is included - bracketed versions are available.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR400C15MLJC2T AirTAC Filter Regulator NPT1/2 FAQ

AirTAC publishes GFR flow as curves, not as a single rated figure, so we do not quote a number here. Send us your line pressure and air demand and we will confirm the flow from the datasheet for this exact NPT1/2 unit before you order.

Code M sets a manual drain: you open the drain valve by hand to bleed collected water from the polycarbonate bowl. If you cannot schedule that, the automatic (A) and differential-pressure (blank) drain codes are available on other GFR400 variants.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR400C15MLJC2T AirTAC Filter Regulator NPT1/2

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR400C15MLJC2T and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.