The AirTAC GFR400C15MLJF2TK AirTAC Filter Regulator NPT1/2 is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR400C15MLJF2TK is a GFR400 filter regulator: one body removes water and particulate from compressed air through a 40 um element and regulates downstream pressure with a low-pressure type regulator. This configuration has 1/2 in NPT ports, a manual-drain polycarbonate bowl, an embedded square gauge with a psi scale, a reverse/check valve fitted, and no mounting bracket. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing.
This is a genuine AirTAC part. The GFR family is published in sizes 200, 300, 400 and 600 with port sizes from 1/8 to 1 in, a choice of differential-pressure, automatic or manual drains, 40 um standard or 5 um (W) filtration, and gauge scales in MPa, psi or bar. Flow is published as curves rather than a single rating, so ask us to confirm the datasheet figures for your application.
| Model | GFR400C15MLJF2TK AirTAC Filter Regulator NPT1/2 |
|---|---|
| Series | GFR400 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR400 | G-series filter regulator, 400 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR400 · See datasheet · 40 µm |
|---|---|
| One size down | GFR300 |
| One size up | GFR600 |
| Add lubrication | GFC400-C1 (two-unit set) |
Filter and regulate the air feeding a pneumatic press or clamping cylinder circuit, with the low-pressure type regulator suited to circuits that run at reduced pressure below the standard line setting.
Point-of-use preparation for packaging line actuators: the 40 um element strips water and particles before they reach cylinders and directional valves, while the regulator holds a steady downstream setting.
Supply filtered, regulated air to gate and diverter cylinders on a conveyor line; the fitted reverse/check valve blocks backflow in the line downstream of the unit.
Size and port set the air capacity: step up from 200 to 600 as your flow demand grows, and match the port to your piping - here 1/2 in NPT (PT is the standard thread; G and NPT are the order options). Choose the drain: differential-pressure (default), automatic (A) or manual (M, as on this unit). Choose the filter grade: 40 um standard or 5 um with code W. Gauge scale is MPa, psi or bar; this unit carries the embedded square gauge on psi. The bracket is omitted on this code (J). Because flow is published as curves rather than a single rating, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR400 as curves, not as a single rated figure, so we do not quote a number here. Send us your application details and we will confirm the datasheet flow figures and sizing before you order.
This code carries M, a manual drain: the bowl is emptied by operating the drain when condensate collects. The GFR family is also available with automatic (A) or differential-pressure drains; tell us your duty and we will quote the matching code.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.