The AirTAC GFR400C15NT AirTAC Filter Regulator, NPT1/2 is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR400C15NT is a filter regulator: one body that removes water and particulate from compressed air and holds the downstream pressure at your setpoint. This size 400 unit has a 1/2 in NPT port, a 40 um standard filter element and a differential-pressure drain. The standard regulator covers an adjustment range of 0.15-0.9 MPa (20-130 psi) with a maximum inlet pressure of 1.0 MPa (145 psi), and the unit operates from -5 to 70 C (non-freezing). No gauge is fitted (code N) and a mounting bracket is included. The bowl on the 400 size is polycarbonate; only the 600 size uses an aluminium alloy bowl.
It is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 in, and options include a 5 um element (code W), automatic or manual drains, gauged variants and G or NPT threads - PT is the standard thread. Flow is published as curves rather than a single rated figure, so ask us to confirm sizing and datasheet figures for your application on request.
| Model | GFR400C15NT AirTAC Filter Regulator, NPT1/2 |
|---|---|
| Series | GFR400 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR400 | G-series filter regulator, 400 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR400 · See datasheet · 40 µm |
|---|---|
| One size down | GFR300 |
| One size up | GFR600 |
| Add lubrication | GFC400-C1 (two-unit set) |
Conditioning the air drop that feeds tool-clamp and tool-change cylinders on a machining centre, holding a set pressure while stripping water and particulate from shop air.
Filtered, regulated air for the diverters, pushers and sealing cylinders on a carton or blister packaging conveyor, where pressure drift causes mis-cycles and rejected packs.
A filter regulator at each workshop air drop, giving individual machines their own set pressure instead of running the whole header at one compromise value.
Choose the size by the flow your line needs: 200, 300, 400 and 600 step up in port and capacity, and this 400 unit carries a 1/2 in port. Drain choice is real: differential-pressure (this unit, the default), automatic (A) for hands-off condensate handling, or manual (M). Filter grade is 40 um standard; specify W for the 5 um element where finer filtration is required. Gauge options are round or square with MPa, psi or bar scales - this unit is supplied without a gauge (code N). Thread is NPT here; PT is the standard and G (BSPP) is also available. A bracket is included. Because AirTAC publishes flow as curves, not a single rating, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so we do not quote a number. Send us your port size, working pressure and air demand and we will confirm sizing against the datasheet on request.
No. The N in GFR400C15NT means no gauge is fitted. Other GFR variants carry an embedded square gauge or an optional external round gauge with MPa, psi or bar scales - ask us if you need a gauged version.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.