The AirTAC AirTAC 4V210-08 Solenoid Valve, 4V200 Series (4V21008A-W) is a genuine 5/2-way single solenoid (spring return) solenoid valve with W ports and an effective area of 17.0 mm² (Cv 1.0). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The 4V21008A-W is the -W variant of the 4V210-08A: a 5/2-way, single-solenoid, spring-return valve for double-acting cylinders and pneumatic actuators. In one coil position the extend side is pressurised while the retract side exhausts; de-energising lets the spring snap the spool home. Choose it wherever the machine must always settle back to a known position after a stop or a restart.
Flow sits at 17.0 mm2 (Cv 1.0), enough for ~O32-50 mm bore cylinders, and the valve tolerates 5 shifts per second with a response of 0.05 s or below. The AC220V coil takes just 4.5 VA through its terminal box on PT1/4 ports; the 220 g aluminium spool body needs no lubrication and only air filtered to 40 um. Shipped as a genuine AirTAC component.
| Model | AirTAC 4V210-08 Solenoid Valve, 4V200 Series (4V21008A-W) |
|---|---|
| Series | 4V200 solenoid valve (spool type) |
| Valve type | 5/2-way |
| Function | Single solenoid (spring return) |
| Port size | W |
| Exhaust port | W |
| Effective area (Cv) | 17.0 mm² (Cv 1.0) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 5 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 220 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 17.0 mm² |
|---|---|
| Flow coefficient | Cv 1.0 |
| Response time | ≤ 0.05 s |
| Coil power | AC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 2 | Body size (4V200) — sets port & flow. |
| 1 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -W | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V210 (single), 4V220 (double), 4V230C/E/P (5/3 center). Add the voltage suffix when ordering.
A ~O32 mm diverter cylinder, fed at Cv 1.0, swings totes between two lanes; the spring return drops the diverter clear whenever the AC220V coil is cut.
Repetitive lift-lower motions suit the 5 cycle-per-second rating and 0.05 s response, with the return stroke guaranteed by the spring rather than by software timing.
Technicians toggle one coil to cycle a test cylinder through its stroke; the terminal-box AC220V coil at 4.5 VA runs straight from standard workshop supply.
If your bore is small and speed unimportant, the 4V100 body at Cv 0.6 does the same job more cheaply; if strokes are long or the bore grows past ~O50 mm, move to the 4V300 at Cv 1.65. Need the cylinder to stay put when power fails? Pick the double-solenoid 4V220-08 (memory) or the closed-centre 5/3 4V230C-08 (Cv 0.8, 3 cycles per second) - and back any load-holding duty with a check valve or mechanical brake where a dropped load is a risk. Single valves thread straight into the circuit, or several can share one manifold base. When replacing, verify five items: 4V200 body size, function 10, 1/4 in PT porting, AC220V coil, terminal entry.
Quick checklist
Check five points and it drops in: 4V200 body size, function 10 (single solenoid, spring return), 1/4 in PT inlet and outlet ports (the exhaust on this body is 1/8 in), AC220V coil at 4.5 VA, and terminal-box entry. Flow is Cv 1.0 (17.0 mm2) with an operating band of 0.15-0.8 MPa and a 1.2 MPa proof pressure.
No lubrication is required, but the air must pass a 40 um filter element and pressure must stay within 0.15-0.8 MPa. The valve works from -20 to +70 C, insulation is class B, and the manual override can be specified as locking or non-locking.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.