The AirTAC 4V210-08 Solenoid Valve, 4V200 Series (4V21008BT-W) is a genuine 5/2-way single solenoid (spring return) solenoid valve with PT1/4 ports and an effective area of 17.0 mm² (Cv 1.0). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The 4V21008BT-W is AirTAC's 4V200-series 5/2 single-solenoid directional control valve built for NPT 1/4in piping, a DC24V coil drawing 3.0 W, and terminal-box wiring. Its -W suffix marks the external-pilot construction: instead of tapping pilot air from the main supply internally, the pilot stage is fed through a separate external pilot port. That keeps shifting dependable even when line pressure runs low or the circuit sits at vacuum or low pressure. Electrically it behaves as a spring-return valve - energise the solenoid to send air to one side of a double-acting cylinder, cut the signal and the internal spring drives the spool back, so a constant electrical signal is needed to hold the extended position.
On the flow side this body sits at an effective area of 17.0 mm2 (Cv 1.0), good for cycle rates up to 5 per second, with a response time of 0.05 s or better. The valve weighs 220 g, runs on 0.15-0.8 MPa of filtered air (40 um element), carries an IP65 terminal box, and suits double-acting cylinders in the ~O32-50 mm bore range. Lubrication is not required and the aluminium-alloy body can mount singly or on an integrated manifold base.
| Model | AirTAC 4V210-08 Solenoid Valve, 4V200 Series (4V21008BT-W) |
|---|---|
| Series | 4V200 solenoid valve (spool type) |
| Valve type | 5/2-way |
| Function | Single solenoid (spring return) |
| Port size | PT1/4 |
| Exhaust port | PT1/8 |
| Effective area (Cv) | 17.0 mm² (Cv 1.0) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 5 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 220 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 17.0 mm² |
|---|---|
| Flow coefficient | Cv 1.0 |
| Response time | ≤ 0.05 s |
| Coil power | AC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 2 | Body size (4V200) — sets port & flow. |
| 1 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -08 | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V210 (single), 4V220 (double), 4V230C/E/P (5/3 center). Add the voltage suffix when ordering.
The external pilot lets this valve switch a double-acting actuator even where main-line pressure is too weak to shift an internally piloted spool, such as vacuum transfer or low-pressure conveying lines.
With Cv 1.0 and up to 5 cycles per second at 0.05 s response, it keeps up with push-off, reject and divert cylinders on packaging and cartoning lines that run NPT plumbing.
Spring return makes it a natural fit for clamp cylinders on assembly stations: power or signal loss retracts the clamp, and the ~O32-50 mm bore range covers most swing clamps and workholding fixtures.
Size the valve to the cylinder, not the other way round. For bores below ~O32 mm or slow, light-duty strokes, the 4V100 (Cv 0.6) is the leaner pick; for bores above ~O50 mm or faster cycle demand, step up to the 4V300 (Cv 1.65). Within the 4V200 body, choose function 10 (this spring-return single solenoid) when a lost signal must retract the actuator; choose 20 (double solenoid, memory) when a pulse should latch position; choose 30C/E/P only if you need a true 5/3 center - and remember those flow less (Cv 0.8). Mounting on a manifold base saves plumbing when several valves sit side by side.
For a like-for-like replacement, match all five points: 4V200 body, function 10, NPT 1/4in port, DC24V coil, terminal entry - plus the -W external-pilot option, which is part of the part number and changes the pilot plumbing. If your machine relies on the valve to hold a load, verify the circuit: for guaranteed load holding add a pilot-operated check valve at the cylinder ports or a mechanical brake rather than relying on the valve alone.
Quick checklist
It is a 5/2 valve with an effective area of 17.0 mm2 (Cv 1.0), so it directs compressed air to double-acting cylinders and actuators, typically in the ~O32-50 mm bore range, at up to 5 cycles per second. It is not suitable for single-acting cylinders, which need a 3/2 valve.
The standard 4V210 feeds its pilot from the main supply internally. The -W version takes pilot air through a separate external port, so the spool still shifts reliably when main pressure is low or the circuit runs at vacuum or low pressure. You plumb the pilot line separately and supply it with adequate clean, filtered pilot air.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.