The AirTAC 4V220-06B Solenoid Valve, 5/2-way, PT1/8, DC24V, terminal entry (4V22006B) is a genuine 5/2-way double solenoid (memory) solenoid valve with PT1/8 ports and an effective area of 17.0 mm² (Cv 1.0). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The 4V220-06B is a double-solenoid 5/2-way valve that directs compressed air to double-acting cylinders and actuators with a memory function—the spool stays in its last pulsed position when power is removed, held by land friction and balanced pressure without springs or holding current. This makes it ideal for applications where the actuator must remain stationary during a power cycle or E-stop event, eliminating the need for a continuous electrical signal.
Built on the 4V200 body, it delivers an effective area of 17.0 mm² (Cv 1.0, catalog figure for the 4V210-08) and suits cylinders in the ~Ø32-50 mm range. The DC24V coil draws just 3.0 W, and the valve responds in 0.05 s or less. This terminal-box version comes with 1/8-inch PT ports and weighs 320 g.
| Model | AirTAC 4V220-06B Solenoid Valve, 5/2-way, PT1/8, DC24V, terminal entry (4V22006B) |
|---|---|
| Series | 4V200 solenoid valve (spool type) |
| Valve type | 5/2-way |
| Function | Double solenoid (memory) |
| Port size | PT1/8 |
| Exhaust port | PT1/8 |
| Effective area (Cv) | 17.0 mm² (Cv 1.0) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 5 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 320 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 17.0 mm² |
|---|---|
| Flow coefficient | Cv 1.0 |
| Response time | ≤ 0.05 s |
| Coil power | AC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 2 | Body size (4V200) — sets port & flow. |
| 2 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -06 | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V210 (single), 4V220 (double), 4V230C/E/P (5/3 center). Add the voltage suffix when ordering.
The memory function holds a clamp or fixture in place during a power loss, preventing workpiece release without requiring constant power to the coil.
Pulse the solenoid to shift a gate or diverter on a conveyor line; the valve holds the position even if the control system powers down between cycles.
Controls double-acting pushers and presses in semi-automated assembly cells where the cylinder must stay extended or retracted during tool changes or pauses.
Choose the 4V220-06B when you need a 5/2 valve that retains its state without power—useful for clamping or holding a cylinder position through a machine stop. If your cylinder is smaller (below Ø32 mm), the 4V100 series (Cv 0.6) may be a better fit; for larger bores or faster cycle rates, step up to the 4V300 (Cv 1.65). The double-solenoid memory function is distinct from a spring-return single solenoid (4V210): it requires only a pulse to shift and holds that position indefinitely.
When replacing an existing valve, match five points: body size (4V200), function (double solenoid 5/2), port and thread (1/8-inch PT), coil voltage (DC24V), and electrical entry (terminal box). The valve can be used standalone or on a manifold base for multi-valve assemblies.
Quick checklist
With an effective area of 17.0 mm² (Cv 1.0, catalog figure for the 4V210-08), it suits double-acting cylinders roughly Ø32-50 mm. Smaller cylinders may overspeed; larger ones may cycle slower than desired. Always size based on required force, speed, and operating pressure.
The spool remains in its last pulsed position through land friction and balanced pressure—no springs, magnets, or holding current are involved. While it holds position on power loss, it is not a safety-rated holding device. For suspended or critical loads, add a pilot-operated check valve or mechanical brake at the cylinder ports.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.