The AirTAC 4V220-06E Solenoid Valve, 5/2-way, PT1/8, AC24V, terminal entry (4V22006E) is a genuine 5/2-way double solenoid (memory) solenoid valve with PT1/8 ports and an effective area of 17.0 mm² (Cv 1.0). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The AirTAC 4V220-06E is a 5/2-way double-solenoid valve that directs compressed air to double-acting cylinders and actuators, holding its last spool position even when electrical power is removed. This memory function makes it ideal for sequences where the actuator must stay put during an E-stop or cycle interruption without needing a constant holding current.
Belonging to the 4V200 body class, it delivers an effective area of 17.0 mm² (Cv 1.0, catalog figure for the 4V210-08) and suits cylinders roughly in the Ø32–50 mm range. The AC24V coil draws 5.0 VA, and the valve responds in 0.05 seconds or less. This specific model comes with a terminal-box electrical entry and PT (Rc) tapered threads on its 1/8-inch ports.
| Model | AirTAC 4V220-06E Solenoid Valve, 5/2-way, PT1/8, AC24V, terminal entry (4V22006E) |
|---|---|
| Series | 4V200 solenoid valve (spool type) |
| Valve type | 5/2-way |
| Function | Double solenoid (memory) |
| Port size | PT1/8 |
| Exhaust port | PT1/8 |
| Effective area (Cv) | 17.0 mm² (Cv 1.0) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 5 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 320 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 17.0 mm² |
|---|---|
| Flow coefficient | Cv 1.0 |
| Response time | ≤ 0.05 s |
| Coil power | AC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 2 | Body size (4V200) — sets port & flow. |
| 2 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -06 | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V210 (single), 4V220 (double), 4V230C/E/P (5/3 center). Add the voltage suffix when ordering.
In a packaging line, a diverter gate must stay in its last commanded position if a safety circuit cuts power. The 4V220-06E memory spool holds the gate’s cylinder in place without air consumption or holding current, resuming only on the next deliberate pulse.
A welding fixture uses this valve to clamp a part. The double-solenoid memory keeps the clamp engaged after the operator releases the cycle-start buttons, eliminating the risk of a spring-back release during the weld sequence.
Controlling a small press cylinder, the 4V220-06E holds the ram in the advanced position during a dwell timer. The AC24V coil integrates easily into the machine’s existing control transformer circuit, and the 0.05 s response keeps the press cycle crisp.
Choose the 4V220-06E when your application needs a double-acting cylinder to hold position on power loss without a spring return. For smaller cylinders below Ø32 mm, stepping down to the 4V100 series (Cv 0.6) often gives better fine control; for larger bores or faster cycle times, the 4V300 series (Cv 1.65) provides the extra flow. This valve can be used as a single unit or ganged on a manifold base for multi-cylinder stations.
When replacing an existing valve, match these five points: body size (4V200), function (double-solenoid 5/2, code 20), port size and thread (1/8-inch PT), coil voltage (AC24V), and electrical entry (terminal box). The AC24V coil is common in control panels with a 24V AC transformer supply.
Quick checklist
With an effective area of 17.0 mm² (Cv 1.0, catalog figure for the 4V210-08), it is well-matched to double-acting cylinders in the Ø32–50 mm range. It can cycle up to 5 times per second, making it suitable for general automation tasks that do not require the higher flow of a 4V300-series valve.
The spool stays in the position it was last pulsed to, held by land friction and balanced pressure. There is no spring to move it and no holding current required. Note that this is not a magnetic latch; it is a purely pneumatic-mechanical hold. For suspended-load safety, always add a pilot-operated check valve or mechanical brake at the cylinder.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.