The AirTAC AirTAC 4V230E-08CI Solenoid Valve, 5/3-way, exhaust center, PT1/4, AC110V, grommet entry (4V230E08CI) is a genuine 5/3-way 5/3 double solenoid — closed center solenoid valve with 230E08CI ports and an effective area of 13.6 mm² (Cv 0.8). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
This 4V230E-08CI is a 5/3-way pneumatic solenoid valve from the AirTAC 4V200 series, configured with an exhaust center. When both solenoids are de-energized, the spool moves to its middle position, connecting both cylinder ports (A and B) to exhaust while blocking the inlet. This allows a double-acting cylinder to float freely, enabling manual positioning or free movement when air pressure is removed.
Supplied with a pre-wired grommet entry and a 0.5 m flying lead for AC110V operation, this valve simplifies electrical installation in DIN-rail setups. It delivers an effective area of 13.6 mm² (Cv 0.8) and weighs 360 g, making it a solid choice for mid-range automation tasks. The aluminum-alloy body carries an IP65 protection rating and responds in 0.05 seconds or less, ensuring dependable cycle control.
| Model | AirTAC 4V230E-08CI Solenoid Valve, 5/3-way, exhaust center, PT1/4, AC110V, grommet entry (4V230E08CI) |
|---|---|
| Series | 4V200 solenoid valve (spool type) |
| Valve type | 5/3-way |
| Function | 5/3 double solenoid — Closed center |
| Port size | 230E08CI |
| Exhaust port | 230E08CI |
| Effective area (Cv) | 13.6 mm² (Cv 0.8) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 3 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 360 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 13.6 mm² |
|---|---|
| Flow coefficient | Cv 0.8 |
| Response time | ≤ 0.05 s |
| Coil power | AC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 2 | Body size (4V200) — sets port & flow. |
| 3 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -230E08CI | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V210 (single), 4V220 (double), 4V230C/E/P (5/3 center). Add the voltage suffix when ordering.
In ergonomic lift-assist arms, the exhaust center lets the operator manually reposition the tool when the valve is neutral, providing intuitive, free-floating movement without fighting trapped air pressure.
Controls double-acting cylinders on packaging line diverters. The float condition prevents a jammed gate from being force-driven, reducing product damage during a machine halt.
Used in assembly fixtures where a clamp must engage for a process step, then fully release both sides to exhaust so the part can be freely removed by a pick-and-place unit.
Choose this 5/3 exhaust-center valve when your application requires the actuator to go limp at rest—common in manual load-assist or clamping stations where the tool must be freely movable upon an E-stop. If you need the cylinder to hold position under pressure loss, step to the 4V230C-08 (closed center). For smaller O20-25 mm cylinders, the 4V100 series (Cv 0.6) is a better fit; for larger O63-100 mm bores demanding higher flow, consider the 4V300 series (Cv 1.65).
When replacing an existing valve, match five points: the 4V200 body size, the 5/3 exhaust-center function, the 1/4-inch PT port, the AC110V coil voltage, and the grommet electrical entry. This model can be used as a single unit or mounted on a 4V200 manifold base for grouped valve islands.
Quick checklist
In the unactuated center position, both cylinder ports (A and B) are connected to the exhaust ports while the pressure inlet is blocked. This means a double-acting cylinder connected to the valve will have no trapped pressure and can be moved freely by hand or external forces—a condition often called 'float'.
Yes, the core valve body and pneumatic function are identical. The difference is the electrical entry: this 'I' model comes with a 0.5 m flying lead and a grommet for a DIN-style connector, whereas the standard terminal box uses a PG9 gland. Ensure your wiring plan accommodates the pre-wired lead length.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.