The AirTAC AirTAC 4V330E-08E Solenoid Valve, 5/3-way, exhaust center, PT1/4, AC24V, terminal entry (4V330E08E) is a genuine 5/3-way 5/3 double solenoid — exhaust center solenoid valve with 330E08E ports and an effective area of 21.3 mm² (Cv 1.25). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The AirTAC 4V330E-08E is a 5/3-way double solenoid valve that directs compressed air to double-acting cylinders and actuators, with an exhaust center position that vents both cylinder ports to atmosphere when the valve is at rest. This allows the actuator rod to float freely, making it the go-to choice for manual positioning, safety circuits where pressure must be fully relieved at stop, or applications requiring a cylinder to be moved by an external force without back-pressure resistance.
Built on the 4V300 aluminum-alloy body with 1/4-inch PT (Rc) threaded ports, this valve has an effective area of 21.3 mm² (Cv 1.25) and a maximum cycling speed of 3 cycles per second. The AC24V coil draws 5.0 VA and the spool responds in 0.05 seconds or less. With IP65 protection and a weight of 450 g, it suits ~50-80 mm bore cylinders where a floating center is needed.
| Model | AirTAC 4V330E-08E Solenoid Valve, 5/3-way, exhaust center, PT1/4, AC24V, terminal entry (4V330E08E) |
|---|---|
| Series | 4V300 solenoid valve (spool type) |
| Valve type | 5/3-way |
| Function | 5/3 double solenoid — Exhaust center |
| Port size | 330E08E |
| Exhaust port | 330E08E |
| Effective area (Cv) | 21.3 mm² (Cv 1.25) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 3 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 450 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 21.3 mm² |
|---|---|
| Flow coefficient | Cv 1.25 |
| Response time | ≤ 0.05 s |
| Coil power | AC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 3 | Body size (4V300) — sets port & flow. |
| 3 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -330E08E | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V310 (single), 4V320 (double), 4V330C/E/P (5/3 center). Add the voltage suffix when ordering.
Ideal for assembly stations where an operator needs to manually slide a fixture or tooling plate into place after the cylinder reaches its mid-stroke. The exhaust center removes all air resistance, allowing smooth, effort-free manual adjustment.
Used in clamping systems where the clamp must fully retract and release all pressure at the center position for safe part loading. The exhaust center guarantees no residual energy is stored in the cylinder, preventing accidental clamp activation.
Controls a pneumatic stop gate on a conveyor line. The valve extends the gate to stop a pallet, then shifts to exhaust center to let the pallet push the gate open against no back-pressure, creating a passive, low-impact release.
Choose the 4V330E-08E when your double-acting cylinder needs to be completely depressurized at the mid-stroke stop, allowing the rod to move without resistance. If you need the cylinder to hold position under load at center, switch to the closed-center 4V330C variant; for a pressure-center application, use the 4V330P. This 5/3 exhaust-center valve is sized between the smaller 4V200 series (Cv 1.0) and the larger 4V400 (Cv 2.82), so it fits cylinders in the ~50-80 mm bore range. When replacing an existing valve, match the 4V300 body, 5/3 exhaust-center function, 1/4-inch port, AC24V coil, terminal box entry, and PT thread to ensure a drop-in fit.
Quick checklist
In the center position, both cylinder ports (A and B) are connected to the exhaust ports, allowing air to escape freely. This means the cylinder rod is not held in place by air pressure and can be moved by an external force, effectively letting the actuator 'float'.
No, the 4V330E-08E is built with an AC24V solenoid that relies on the alternating current's impedance to limit current. Connecting it to a DC supply will cause a short circuit and burn out the coil instantly. You must use a stable AC24V source; for DC control, select the DC24V (B) or DC12V (F) voltage code.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.