The AirTAC 4V330P-08E Solenoid Valve, 5/3-way, pressure center, PT1/4, AC24V, terminal entry (4V330P08E) is a genuine 5/3-way 5/3 double solenoid — exhaust center solenoid valve with PT1/4 ports and an effective area of 21.3 mm² (Cv 1.25). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The AirTAC 4V330P-08E is a 5/3-way pneumatic solenoid valve engineered to command double-acting cylinders and actuators where applying balanced pressure at the mid-stroke is required. In its center position, both cylinder ports are pressurized simultaneously, which can be used to hold a load against external forces or to create a controlled opposition force, giving you an alternative to a fully blocked center. This model is configured with a terminal-style electrical entry and an AC24V coil drawing 5.0 VA.
Part of the 4V300 series, this valve body provides an effective area of 21.3 mm² (Cv 1.25, catalog figure for the 4V330C-10) and typically suits cylinders in the ~Ø50-80 mm range. The spool shifts in 0.05 seconds or less, and the aluminum alloy body is rated IP65 for reliable service in challenging industrial environments. At 450 g, it is a compact yet capable control element for mid-sized pneumatic systems.
| Model | AirTAC 4V330P-08E Solenoid Valve, 5/3-way, pressure center, PT1/4, AC24V, terminal entry (4V330P08E) |
|---|---|
| Series | 4V300 solenoid valve (spool type) |
| Valve type | 5/3-way |
| Function | 5/3 double solenoid — Exhaust center |
| Port size | PT1/4 |
| Exhaust port | PT1/4 |
| Effective area (Cv) | 21.3 mm² (Cv 1.25) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 3 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 450 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 21.3 mm² |
|---|---|
| Flow coefficient | Cv 1.25 |
| Response time | ≤ 0.05 s |
| Coil power | AC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 3 | Body size (4V300) — sets port & flow. |
| 3 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -08 | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V310 (single), 4V320 (double), 4V330C/E/P (5/3 center). Add the voltage suffix when ordering.
In pressing or clamping operations, the pressure-center function applies force to both sides of a double-acting cylinder, creating a controlled opposing force that can be used for delicate part alignment or to prevent drift during a process step.
For material handling systems that need to stop a vertical load at a mid-point, the 4V330P-08E pressurizes both cylinder chambers to balance the load, offering a different dynamic than a simple blocked-center hold.
Used in test stands where a specific, repeatable pre-load or counter-force is needed on a test specimen, this valve provides a stable dual-pressure state at the cylinder's center position, controlled entirely by the pneumatic circuit.
Choose the 4V330P-08E when your application demands a 5/3 pressure-center function on a 1/4-inch ported base. This valve is a direct fit for systems using a 4V300-series manifold or individual sub-base, and it steps up the flow capacity from the smaller 4V200 body (Cv 1.0) for driving larger cylinders. If your cylinder bore exceeds 80 mm, consider moving to the 4V400 series for its higher Cv of 2.82.
The pressure-center behavior is distinct from the closed-center (30C) or exhaust-center (30E) models, so ensure your circuit logic requires both A and B ports to be pressurized at rest. For a direct replacement, match five key points: the 4V300 body size, the 5/3 pressure-center function, the 1/4-inch PT port, an AC24V coil, and the terminal box electrical connection. This ensures full mechanical and electrical compatibility without modifying your existing manifold or wiring.
Quick checklist
In the center position, when neither solenoid is energized, the 4V330P-08E connects both cylinder ports (A and B) to the supply pressure (P) while blocking the exhaust ports. This pressurizes both sides of a double-acting cylinder, creating a balanced force state that can be used to hold a position against an external load or to apply a controlled opposing force.
Yes, the 4V330P-08E is a standard form-factor replacement. Verify that your current valve is a 4V300-series, 5/3 pressure-center unit with 1/4-inch ports and an AC24V coil. The terminal box entry and PT threads match the most common legacy installations, and the 21.3 mm² effective area provides consistent flow performance for your existing cylinder.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.