verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC300 · Two-Unit Set (filter regulator + lubricator)

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30010ANWK

The AirTAC B52-GFC Copper-Free Air Source Treatment Component B52-GFC30010ANWK is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT3/8" ports, a 5 µm element, a automatic drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT3/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeNot fitted
  • ThreadPT
$83.39 $89.15Save 6% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30010ANWK

The GFC family combines a filter regulator and a lubricator as a two-piece set, covering filtration, pressure regulation and oil-mist lubrication in a single order. This GFC30010ANWK is the size 300 unit with a PT3/8 port, an automatic drain on the filter bowl and the W-suffix 5 um filter element. The regulator section is the standard type with a pressure gauge fitted, and the K suffix adds a reverse (check) valve.

This is a genuine AirTAC part. The G series is offered in sizes 200, 300, 400 and 600 with a choice of ports, drain types, 40 um or 5 um filtration and PT, G or NPT threads. Maximum working pressure is 1.0 MPa (145 psi), working temperature range is -5 to 70 C (non-freezing), and the size 300 bowls are polycarbonate. Flow is published as curves rather than a single rating, so we confirm datasheet figures on request.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30010ANWK Technical Specifications

ModelAirtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30010ANWK
SeriesGFC300 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT3/8" (PT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeNot fitted
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30010ANWK

GFC300G-series two-unit set, 300 body — sets the port range.
10Port size PT3/8". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-10 filter regulator and GL300-10 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC300 · PT3/8" · 5 µm
One size downGFC200
One size upGFC400
Three-unit equivalentGC300-10
Build orderFilter regulator first, lubricator last

Where the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30010ANWK Is Used

engineering

Hydraulics-test rig air section

On a test bench where pneumatic actuation must hold its set pressure through supply dips, the set cleans air to 5 um, regulates it and the check valve limits back-flow at the prep point.

handyman

Maintenance shop service drop

A general maintenance shop air point feeding impact tools and test cylinders: filtered to 5 um, regulated, lubricated and self-draining, with the check-valve version holding the line at the bench.

tune

Printing press auxiliary circuits

Feeding register, roller and clutch cylinders on a press, the two-unit set delivers clean, regulated, lubricated air, with automatic draining and the check-valve feature suiting a press pit installation.

Is the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30010ANWK the Right Set?

This is the fully optioned size 300 code: 3/8" port, automatic drain, 5 um W-grade element and a reverse (check) valve in the regulator section. Pick it when you need the finer filtration and the check-valve feature together; drop the K or the W from the code when either is not required. The regulator adjusts 0.15-0.9 MPa (20-130 psi) in this automatic-drain configuration. PT is the standard thread; G (BSPP) and NPT are catalogue options to specify when ordering. A bracket is available for panel fixing.

Flow is published as curves, not a single rated figure, so ask us to confirm sizing from the datasheet against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-10 filter regulator on its own.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30010ANWK FAQ

There is no single rated-flow figure to quote: AirTAC publishes G-series flow as curves. Share your supply pressure, regulated pressure and air demand, and we will confirm the correct size from the datasheet curves on request before ordering.

W changes the filter element from the standard 40 um grade to 5 um, and K fits a reverse (check) valve in the regulator section. Otherwise it decodes the same as GFC30010AN: size 300, PT3/8 port, automatic drain, gauge included, PT thread standard.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30010ANWK

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for B52-GFC30010ANWK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.