verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC300 · Two-Unit Set (filter regulator + lubricator)

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30010LC1W

The AirTAC B52-GFC Copper-Free Air Source Treatment Component B52-GFC30010LC1W is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT3/8" ports, a 5 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT3/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$85.41 $91.21Save 6% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30010LC1W

GFC30010LC1W is AirTAC's G-series two-unit air preparation set for compressed air: a filter-regulator plus a separately mounted lubricator, cleaning the air, holding a set downstream pressure and adding oil mist from one supply connection. This build combines the low-pressure type (L) regulator, the fine 5 um (W) element, the differential-pressure drain and the optional external round gauge scaled in MPa. Ports are PT3/8 in the 300 size.

It is a genuine AirTAC part. The G-series runs from size 200 to 600, with PT, G (BSPP) or NPT threads, 40 um or 5 um filtration, differential-pressure, automatic or manual drains, and MPa, psi or bar gauge scales, so the same function is available in other ports and configurations. Flow is published as curves rather than a single rating; ask us and we will confirm sizing and datasheet figures on request.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30010LC1W Technical Specifications

ModelAirtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30010LC1W
SeriesGFC300 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT3/8" (PT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — round, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30010LC1W

GFC300G-series two-unit set, 300 body — sets the port range.
10Port size PT3/8". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-10 filter regulator and GL300-10 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC300 · PT3/8" · 5 µm
One size downGFC200
One size upGFC400
Three-unit equivalentGC300-10
Build orderFilter regulator first, lubricator last

Where the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30010LC1W Is Used

view_module

Pick-and-place modules on an electronics line

Supplies the small placement and ejection cylinders on an electronics assembly module, where the 5 um element keeps fine contamination away from compact components and the low-pressure type suits light actuation.

science

Purge and actuation air in an analytical enclosure

Feeds purge jets and small actuators inside an analyser or test enclosure: finely filtered, low-pressure regulated air, with the external round MPa gauge readable on the enclosure panel.

valve

Pilot air on a water treatment valve skid

Mounted ahead of the air-piloted butterfly and diaphragm valves on a treatment skid, providing finely filtered, oiled pilot air regulated at the lower pressures the positioners and pilots require.

Is the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30010LC1W the Right Set?

This code bundles three real choices: the low-pressure L regulator type, the 5 um (W) element instead of the 40 um standard, and the external round MPa gauge in place of the embedded square gauge. The 300 size with PT3/8 ports sits mid-range in the family; step to 200 for compact lines or to 400/600 for larger headers. The differential-pressure drain is standard here, with automatic and manual drain codes available, and the thread is PT as the standard, with G (BSPP) and NPT as catalogue options. Compressed air only, -5 to 70 C, non-freezing.

Ask us to confirm the adjust range of the low-pressure type against your set pressure, and to check the flow curve against your demand - flow is published as curves, not a single rating - before you order the GFC30010LC1W.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-10 filter regulator on its own.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30010LC1W FAQ

We can confirm it from the datasheet on request: AirTAC publishes flow for this series as curves across working pressure, not as a single rated figure, so we do not state one number. Send us your pressure and demand and we will verify the sizing.

The GFC set combines the filter and regulator in one body with the lubricator as a second, separately mounted unit. The GC combination is three separate units - filter, regulator and lubricator. Both deliver filtered, regulated, lubricated air; choose by plumbing and mounting preference, and we can quote either in this 300 size with PT3/8 ports.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30010LC1W

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for B52-GFC30010LC1W and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.