verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC300 · Two-Unit Set (filter regulator + lubricator)

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30010MC1WK

The AirTAC B52-GFC Copper-Free Air Source Treatment Component B52-GFC30010MC1WK is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT3/8" ports, a 5 µm element, a manual drain and regulation over 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT3/8"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade5 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$96.76 $102.84Save 5% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30010MC1WK

GFC30010MC1WK is a genuine AirTAC G-series two-unit set combining a filter regulator with a lubricator on a 3/8 in PT ported line, and the trailing K code adds a reverse (check) valve in the regulator section. The M code sets a manual drain on the filter bowl, C1 selects the external round gauge with an MPa scale, and W fits the 5 um filter element instead of the standard 40 um. With manual drainage, the regulator adjusts from 0.05 to 0.9 MPa (7-130 psi); for the exact behaviour of the K-option check valve in your circuit, we confirm the details from the datasheet on request.

The medium is compressed air, maximum working pressure is 1.0 MPa (145 psi) and the temperature range is -5 to 70 C (non-freezing); at size 300 the bowls are polycarbonate (PC). The GFC family spans sizes 200 to 600, with automatic or differential-pressure drains, the standard 40 um element, embedded square or external round gauges on MPa, psi or bar scales, and G (BSPP) or NPT threads available as catalogue options. Flow is published as curves, not a single rated figure, so we confirm sizing and datasheet figures on request.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30010MC1WK Technical Specifications

ModelAirtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30010MC1WK
SeriesGFC300 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT3/8" (PT thread)
Filtering grade5 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — round, MPa scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30010MC1WK

GFC300G-series two-unit set, 300 body — sets the port range.
10Port size PT3/8". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-10 filter regulator and GL300-10 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC300 · PT3/8" · 5 µm
One size downGFC200
One size upGFC400
Three-unit equivalentGC300-10
Build orderFilter regulator first, lubricator last

Where the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30010MC1WK Is Used

bolt

Clamp-pressure hold circuits

Used where a clamped workpiece must stay pressed if shop air dips: the check valve in the regulator section backs up the downstream setting while the set keeps the clamp cylinder filtered, regulated and lubricated.

factory

Pilot-air supply on a production line

Feeds the pilot-air circuit for line valves and actuators, where the 5 um element protects sensitive pilot spools and the check valve isolates the pilot branch from upstream disturbances.

engineering

Fixture and jig control panels

Mounted at the panel feeding jig and fixture cylinders, giving the setter an MPa gauge reading, clean regulated air, oil mist for the cylinders and check-valve isolation of the panel circuit.

Is the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30010MC1WK the Right Set?

This code differs from GFC30010MC1W only in the K suffix, which fits a reverse (check) valve - choose it where the downstream circuit must not simply empty back through the set. Size 300 with the 3/8 in port is the mid step (200 to 600, 1/8 in to 1 in); we verify the step against the published flow curves for your demand before you order. The manual drain allows regulation from 0.05 to 0.9 MPa (7-130 psi) but needs a routine bleed, while automatic and differential-pressure drain codes start at 0.15 MPa (20 psi). The 5 um element serves finer point-of-use air than the standard 40 um, the C1 round gauge reads in MPa, and thread is PT as standard with G (BSPP) and NPT as orderable options. Ask us to confirm sizing against the flow curves before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-10 filter regulator on its own.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30010MC1WK FAQ

AirTAC publishes G-series capacity as flow curves, not as one rated number, so we do not quote a figure here. Tell us your line pressure and air demand and we will confirm the correct size and the full datasheet figures on request before you order.

The K suffix means a reverse (check) valve is fitted in the regulator section of this set, which distinguishes it from the plain GFC30010MC1W. For the exact role it plays in your circuit, we confirm the details from the datasheet on request.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30010MC1WK

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for B52-GFC30010MC1WK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.