verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC300 · Two-Unit Set (filter regulator + lubricator)

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30010MLC1W

The AirTAC B52-GFC Copper-Free Air Source Treatment Component B52-GFC30010MLC1W is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT3/8" ports, a 5 µm element, a manual drain and regulation over 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT3/8"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade5 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$85.41 $91.21Save 6% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30010MLC1W

GFC30010MLC1W is an AirTAC G-series two-unit air-treatment set: a filter regulator plus a lubricator paired as one set. It removes water and particulate from compressed air, regulates downstream pressure and adds oil mist for the air cylinders and tools that follow it. This 300-size set has PT3/8 ports (PT is the standard thread; G and NPT are catalogue options), a manual drain on the bowl, the finer 5 um W filter element instead of the 40 um standard, the L low-pressure type variant, and an external round pressure gauge reading in MPa. Max working pressure is 1.0 MPa (145 psi); with manual drain the regulator adjustment range is 0.05-0.9 MPa (7-130 psi). Operating temperature is -5 to 70 C, non-freezing. At size 300 the bowls on both the filter regulator and the lubricator are PC (polycarbonate).

This is a genuine AirTAC part. The GFC two-unit family is also available in 200, 400 and 600 sizes, with a choice of ports, differential-pressure or automatic drain, 40 um or 5 um filtration, square or round gauges in MPa, psi or bar scales, and a reverse/check valve. Because rated flow is published as curves rather than a single figure, ask us to confirm flow and datasheet figures for your application on request.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30010MLC1W Technical Specifications

ModelAirtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30010MLC1W
SeriesGFC300 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT3/8" (PT thread)
Filtering grade5 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — round, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30010MLC1W

GFC300G-series two-unit set, 300 body — sets the port range.
10Port size PT3/8". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-10 filter regulator and GL300-10 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC300 · PT3/8" · 5 µm
One size downGFC200
One size upGFC400
Three-unit equivalentGC300-10
Build orderFilter regulator first, lubricator last

Where the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30010MLC1W Is Used

precision_manufacturing

CNC machining cell

Filtering, regulating and oil-mist lubricating the air that feeds pneumatic clamps, tool-change actuators and chip-clearing blasts on a CNC machining centre.

build

Truck and plant maintenance bays

Supplying conditioned, lubricated air to the impact wrenches, ratchets and air hammers used in commercial-vehicle and plant service workshops.

conveyor_belt

Case-packing line

Feeding regulated, lubricated air to the cylinders and grippers that close, case-pack and palletise cartons on a packaging conveyor line.

Is the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30010MLC1W the Right Set?

Work through the real decodable choices. Size and port: 300 carries PT3/8; step down to 200 or up to 400/600 to match the air demand of the line, since larger sizes mean larger ports and more flow. Drain: this set is manual drain (M); differential-pressure is the default and automatic (A) is available where regular bowl draining is impractical. Filtration: the 5 um W element here is finer than the 40 um standard. Gauge: the C1 round gauge reads in MPa; embedded square gauges and psi or bar scales are options. Thread: PT is standard; order G (BSPP) or NPT if your piping needs it. Flow is published as curves, not a single rating, so send us your flow requirement and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-10 filter regulator on its own.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30010MLC1W FAQ

AirTAC publishes flow for the GFC series as curves, not as a single rated figure, so we do not quote a number here. Tell us your required flow and line conditions and we will confirm sizing from the datasheet on request before you order.

The GFC is a two-piece set: a filter regulator body plus a lubricator, covering filtration, regulation and lubrication in one pair. The GC splits the same three functions into three separate units. If a combined filter-regulator plus lubricator suits your panel space, GFC is the tighter choice.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30010MLC1W

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for B52-GFC30010MLC1W and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.