AirTAC GFC300 · Two-Unit Set (filter regulator + lubricator)

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30010NW

The AirTAC B52-GFC Copper-Free Air Source Treatment Component B52-GFC30010NW is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT3/8" ports, a 5 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT3/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeNot fitted
  • ThreadPT
$61.60 $66.81Save 7% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30010NW

The GFC series pairs a filter regulator with a lubricator in one two-unit set, covering filtration, pressure regulation and oil-mist lubrication from a single order. This GFC30010NW is the 300 size with 3/8in PT ports and the W-code 5 um filter element instead of the standard 40 um, for cleaner air to sensitive downstream components. The bowls are polycarbonate (PC) at this size and drain by differential pressure. It is supplied without a gauge, and no reverse valve is fitted. Maximum inlet pressure is 1.0 MPa (145 psi) and the regulator adjusts from 0.15 to 0.9 MPa (20-130 psi). Operating temperature is -5 to 70 C, non-freezing.

This is a genuine AirTAC part. The G series runs from size 200 to 600, so the same two-unit function is available with other port sizes, automatic or manual drains, the standard 40 um element, G (BSPP) or NPT threads in place of PT, and with or without gauges or a reverse (check) valve. AirTAC publishes flow as characteristic curves rather than a single rated figure, so we confirm curve data and the full datasheet for your application on request.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30010NW Technical Specifications

ModelAirtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30010NW
SeriesGFC300 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT3/8" (PT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeNot fitted
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30010NW

GFC300G-series two-unit set, 300 body — sets the port range.
10Port size PT3/8". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-10 filter regulator and GL300-10 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC300 · PT3/8" · 5 µm
One size downGFC200
One size upGFC400
Three-unit equivalentGC300-10
Build orderFilter regulator first, lubricator last

Where the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30010NW Is Used

science

Lab automation actuators

Prepares the air for cylinders and actuators on laboratory automation benches, where the 5 um element keeps particulate out of compact, sensitive mechanisms.

settings_input_component

Pick-and-place grippers

Supplies regulated, lubricated air to gripper cylinders on a pick-and-place module, holding a consistent set pressure for repeatable part handling.

valve

Process-skid pilot air

Feeds pilot-air circuits on a process skid, with the 5 um element helping keep control valves and pilot components clear of fine contamination.

Is the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30010NW the Right Set?

The 300 size matches circuits built around 3/8in PT ports; move to 200 or 400/600 only if those sizes' port options and curve-based flow fit your demand. This unit carries the W code, so the element is 5 um - the right choice when a standard 40 um element leaves too much particulate for the downstream kit; choose the plain code if 40 um is enough. The differential-pressure drain suits steady, continuously running lines; automatic (A) or manual (M) variants exist. No gauge is fitted - order a variant with the embedded square gauge or an external round gauge in MPa, psi or bar scale. PT is the standard thread; G (BSPP) and NPT are catalogue options. Flow is published as curves, not a single rating, so ask us to confirm sizing against your air demand before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-10 filter regulator on its own.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30010NW FAQ

AirTAC publishes flow for this set as characteristic curves, not as one rated figure. Tell us your line pressure and air demand and we will confirm the relevant curve data and datasheet on request before you order.

The blank code gives the standard 40 um element, which suits general actuator and tool protection. The W code in GFC30010NW specifies a 5 um element for finer filtration - the better pick for compact valves, grippers and instrumentation that suffer from fine particulate.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30010NW

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for B52-GFC30010NW and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.