The AirTAC B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015ALC1W is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/2" ports, a 5 µm element, a automatic drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
The GFC30015ALC1W is an AirTAC G-series two-unit air preparation set: a 300-size filter regulator plus a separate lubricator, so filtration, low-pressure regulation and oil-mist lubrication arrive in two pieces. It is drilled for 1/2 inch ports on standard PT thread, has an automatic drain that clears condensate from the filter bowl on its own, a 5 um element for finer filtration than the standard 40 um, and a round external gauge reading in MPa.
It is a genuine AirTAC part, rated for a maximum working pressure of 1.0 MPa (145 psi) and -5 to 70 C non-freezing operation, with polycarbonate bowls on the 300 size. The G series runs from size 200 to 600 with a choice of drain types, filter grades, gauges and PT, G or NPT threads. Flow is published as curves rather than a single rating, so we confirm flow and datasheet figures for your application on request.
| Model | Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015ALC1W |
|---|---|
| Series | GFC300 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT1/2" (PT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Low-pressure type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Automatic drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, MPa scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC300 | G-series two-unit set, 300 body — sets the port range. |
|---|---|
| 15 | Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| A | Drain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-15 filter regulator and GL300-15 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC300 · PT1/2" · 5 µm |
|---|---|
| One size down | GFC200 |
| One size up | GFC400 |
| Three-unit equivalent | GC300-15 |
| Build order | Filter regulator first, lubricator last |
Prepares air for pneumatic actuators on liquid-handling and sample-handling stations, where the 5 um element helps keep fine control valves free of particulate and water.
Conditions plant air for placement-head vacuum circuits and board clamps on an electronics assembly line, holding a low set pressure while the automatic drain handles condensate.
Supplies low-pressure air to clamping and ejection aids around a pharmaceutical tablet press, with 5 um filtration supporting the cleaner air these areas demand.
This 300-size set at 1/2 inch PT suits lines that have outgrown 1/4-inch and 3/8-inch preparation; choose size 200 for smaller ports. The L code selects the low-pressure regulator type; its reduced adjustment span differs from the standard type, so we confirm the exact range from the datasheet on request. The trailing W selects 5 um filtration instead of the standard 40 um - the right call when sensitive pilot valves or instruments sit downstream. C1 adds a round external gauge with an MPa scale; square dials and psi or bar scales are also orderable. Thread stays PT unless you order G or NPT. Flow is published as curves, not a single rating, so ask us to confirm sizing before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-15 filter regulator on its own.
AirTAC publishes G-series flow as curves rather than a single rated figure, so we do not quote a number here. Share your working pressure and consumption and we will confirm sizing against the datasheet curve before you order.
The W code fits a 5 um element instead of the standard 40 um, catching finer particulate ahead of sensitive valves and instruments. Both filter equally on water via the same bowl and automatic drain. We confirm element details from the datasheet on request.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.