AirTAC GFC300 · Two-Unit Set (filter regulator + lubricator)

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015ANW

The AirTAC B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015ANW is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/2" ports, a 5 µm element, a automatic drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeNot fitted
  • ThreadPT
$72.04 $77.51Save 7% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015ANW

GFC30015ANW is a genuine AirTAC G-series two-unit set: a filter-regulator and a lubricator supplied as two pieces that mount together, so the compressed air is filtered, regulated and then lubricated in one pass. The W suffix fits the finer 5 um filter element in place of the standard 40 um grade. This size 300 configuration has PT1/2 ports as standard, an automatic drain on the filter bowl and no gauge fitted; the bowls are polycarbonate at this size, the set handles compressed air at up to 1.0 MPa (145 psi), and it operates between -5 and 70 C (non-freezing).

It is part of the AirTAC G series spanning sizes 200 to 600, and this automatic-drain version adjusts from 0.15 to 0.9 MPa (20-130 psi). Because flow for the series is published as curves rather than a single rating, ask us and we will confirm the datasheet figures for your application.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015ANW Technical Specifications

ModelAirtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015ANW
SeriesGFC300 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT1/2" (PT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeNot fitted
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015ANW

GFC300G-series two-unit set, 300 body — sets the port range.
15Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-15 filter regulator and GL300-15 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC300 · PT1/2" · 5 µm
One size downGFC200
One size upGFC400
Three-unit equivalentGC300-15
Build orderFilter regulator first, lubricator last

Where the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015ANW Is Used

science

Laboratory pneumatic actuation benches

Conditions and lubricates air on a lab test bench driving small actuators and fixtures, where the 5 um element suits instrumentation sensitive to coarser particulate.

air

Pilot-air supply for control valves in a water treatment plant

Provides filtered, regulated and lubricated pilot air to pneumatic positioners and control valves on a treatment line, with the automatic drain coping with humid compressor output.

settings_input_component

Electronic assembly pick-and-place modules

Feeds the vacuum and gripper cylinders of a pick-and-place module on an electronics assembly cell, keeping air clean to 5 um before the lubricator mists the moving seals.

Is the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015ANW the Right Set?

Pick the W code when the downstream equipment tolerates less particulate than the standard 40 um element removes - the 5 um grade is the catalogue's finer option on this family. Size 300 with 1/2 inch ports covers medium-flow circuits; move to 400 or 600 for larger demand. The automatic drain keeps condensate off the element without operator attention. No gauge is fitted (N); specify an embedded square gauge or an external round gauge with MPa, psi or bar scale if you want a set-point visible at the machine. Thread is PT as standard, with G (BSPP) and NPT available to order. Flow is published as curves rather than a single rating, so send your demand figures and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-15 filter regulator on its own.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015ANW FAQ

Sizing depends on flow, and AirTAC publishes G-series flow as performance curves rather than one rated figure, so we do not print a number here. Give us your flow demand and working pressure and we will confirm from the datasheet whether size 300 at 1/2 inch with the 5 um element meets your requirement.

Both are catalogue filter grades on this family. The standard element captures 40 um particles and suits general plant air; the W option captures down to 5 um for equipment that needs cleaner air, such as pilot circuits and instrumentation. This code is the 5 um version; the 40 um equivalent is GFC30015AN.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015ANW

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for B52-GFC30015ANW and will confirm price, stock and lead time — usually within 7-8 hours.