The AirTAC B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015MC1W is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/2" ports, a 5 µm element, a manual drain and regulation over 0.05 - 0.9 MPa (7 - 130 psi).
The AirTAC GFC30015MC1W is a two-unit air preparation set: a 300-size filter regulator paired with a separate lubricator, supplying filtration, regulation and oil-mist lubrication from one 1/2 in PT connection. The W suffix specifies the 5 um fine filter element instead of the standard 40 um, for cleaner air to sensitive valves and tools. This configuration has a manual drain on the bowl and an external round pressure gauge scaled in MPa. It runs on compressed air only, up to 1.0 MPa (145 psi) and -5 to 70 C, and the manual-drain regulator adjusts from 0.05 to 0.9 MPa (7-130 psi). Bowls on the 300 size are polycarbonate.
This is a genuine AirTAC part in the G-series 300 size. The family spans 200, 300, 400 and 600 sizes with 1/8 to 1 in ports, G (BSPP) and NPT thread options, automatic or differential-pressure drains, and a check-valve option. AirTAC publishes flow as curves rather than a single rating, so ask us to confirm sizing and the full datasheet for your application.
| Model | Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015MC1W |
|---|---|
| Series | GFC300 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT1/2" (PT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, MPa scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC300 | G-series two-unit set, 300 body — sets the port range. |
|---|---|
| 15 | Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-15 filter regulator and GL300-15 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC300 · PT1/2" · 5 µm |
|---|---|
| One size down | GFC200 |
| One size up | GFC400 |
| Three-unit equivalent | GC300-15 |
| Build order | Filter regulator first, lubricator last |
Filtering down to 5 um, regulating and lubricating the air feeding paint-spray guns and their atomizing-air regulators on a finishing line, where coarse particles would spoil the finish.
Conditioning the supply to precision pneumatic actuators on laboratory automation equipment, with the 5 um element protecting small pilot valves from particulate fouling.
Supplying clean, regulated, lubricated air to the vacuum generators and gripper cylinders on an electronics pick-and-place module, where fine filtration guards the miniature valve stack.
This is the 300-size, 1/2 in PT set with the W option: a 5 um element in place of the standard 40 um. Choose 5 um when the downstream valves, cylinders or tools need finer particle control; keep 40 um for general duty. Drain is manual on this model, with automatic and differential-pressure as the other catalogue options. The external round gauge reads in MPa; psi and bar scales are alternatives, and thread comes as standard PT with G (BSPP) or NPT to order. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-15 filter regulator on its own.
AirTAC publishes flow for the G-series as curves rather than a single rated figure, so we do not quote one number. Tell us your line pressure and air consumption and we will confirm sizing and supply the datasheet on request.
Choose the W version when finer particle control matters - for example ahead of pilot-operated valves, spray equipment or small actuators. The standard 40 um element suits general cylinder and tool duty. Everything else on this model is unchanged: 1/2 in PT ports, manual drain, MPa round gauge and a separate lubricator.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.