AirTAC GFC300 · Two-Unit Set (filter regulator + lubricator)

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015MC1W

The AirTAC B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015MC1W is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/2" ports, a 5 µm element, a manual drain and regulation over 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT1/2"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade5 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$85.41 $91.21Save 6% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015MC1W

The AirTAC GFC30015MC1W is a two-unit air preparation set: a 300-size filter regulator paired with a separate lubricator, supplying filtration, regulation and oil-mist lubrication from one 1/2 in PT connection. The W suffix specifies the 5 um fine filter element instead of the standard 40 um, for cleaner air to sensitive valves and tools. This configuration has a manual drain on the bowl and an external round pressure gauge scaled in MPa. It runs on compressed air only, up to 1.0 MPa (145 psi) and -5 to 70 C, and the manual-drain regulator adjusts from 0.05 to 0.9 MPa (7-130 psi). Bowls on the 300 size are polycarbonate.

This is a genuine AirTAC part in the G-series 300 size. The family spans 200, 300, 400 and 600 sizes with 1/8 to 1 in ports, G (BSPP) and NPT thread options, automatic or differential-pressure drains, and a check-valve option. AirTAC publishes flow as curves rather than a single rating, so ask us to confirm sizing and the full datasheet for your application.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015MC1W Technical Specifications

ModelAirtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015MC1W
SeriesGFC300 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT1/2" (PT thread)
Filtering grade5 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — round, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015MC1W

GFC300G-series two-unit set, 300 body — sets the port range.
15Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-15 filter regulator and GL300-15 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC300 · PT1/2" · 5 µm
One size downGFC200
One size upGFC400
Three-unit equivalentGC300-15
Build orderFilter regulator first, lubricator last

Where the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015MC1W Is Used

speed

Paint line air supply

Filtering down to 5 um, regulating and lubricating the air feeding paint-spray guns and their atomizing-air regulators on a finishing line, where coarse particles would spoil the finish.

science

Lab automation actuators

Conditioning the supply to precision pneumatic actuators on laboratory automation equipment, with the 5 um element protecting small pilot valves from particulate fouling.

view_module

Electronics assembly pick-and-place

Supplying clean, regulated, lubricated air to the vacuum generators and gripper cylinders on an electronics pick-and-place module, where fine filtration guards the miniature valve stack.

Is the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015MC1W the Right Set?

This is the 300-size, 1/2 in PT set with the W option: a 5 um element in place of the standard 40 um. Choose 5 um when the downstream valves, cylinders or tools need finer particle control; keep 40 um for general duty. Drain is manual on this model, with automatic and differential-pressure as the other catalogue options. The external round gauge reads in MPa; psi and bar scales are alternatives, and thread comes as standard PT with G (BSPP) or NPT to order. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-15 filter regulator on its own.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015MC1W FAQ

AirTAC publishes flow for the G-series as curves rather than a single rated figure, so we do not quote one number. Tell us your line pressure and air consumption and we will confirm sizing and supply the datasheet on request.

Choose the W version when finer particle control matters - for example ahead of pilot-operated valves, spray equipment or small actuators. The standard 40 um element suits general cylinder and tool duty. Everything else on this model is unchanged: 1/2 in PT ports, manual drain, MPa round gauge and a separate lubricator.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015MC1W

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.